Mitel Deutschland GmbH 68635RFP36U-01 ユーザーズマニュアル

ページ / 383
 
OMM Web Service 
 
63 
 
• 
NTP server: The NTP servers used for time synchronization.  
• 
Time zone: Specifies the time zone in which the OMM is operating. This feature is exclusively 
available on the OMM DECT base station. On PC-OMM configurations, the PC time and time zone is 
used. 
 
5.4.1.15   Restarting the OMM 
You can restart the OMM by clicking on the 
Restart button in the top right corner of the System 
Settings page.  
1  Click on the Restart button. 
The 
Restart dialog window opens. 
 
2  In the Restart dialog window, set the following options:  
• 
Discard OMM DB and configuration files: Specifies whether OMM database and configuration data 
is removed from the DECT base station, including the data retrieved from RCS. Local IP configuration 
remains unaffected. This parameter is only available on an OMM DECT base station. 
• 
Reset OMM RFP(s) to factory defaults: Specifies whether all data is removed from the DECT BASE 
STATION including the OMM database, configuration files and local IP configuration. 
Note:  Both options also affect the standby OMM. 
3  Click OK.  
A Restart web page opens and displays a progress bar. The login page is loaded automatically if the 
OMM is reachable again. 
 
5.4.1.16  Updating the OMM 
An 
Update button is available on the System settings web page. Pressing the Update button forces the 
DECT base stations to check for new software and initiates the software update. For more details about 
updating the OMM see the section 7.14.