Configuration and Administration
259
To avoid the DHCP scope within the native VLAN the VLAN ID to be used can be set permanently via
OMC without losing the ability to provide other parameter via DHCP, please see section 7.7.
OMC without losing the ability to provide other parameter via DHCP, please see section 7.7.
7.12.2 BOOT PHASE OF IP RFPS (LOCAL CONFIGURATION)
The PC running the OM Configurator must be a member of the native VLAN for the first configuration,
later on within the voice VLAN set.
later on within the voice VLAN set.
If a wrong or unknown VLAN ID is set, you can overwrite or read the configuration using no VLAN tag on
the switch port in the first six seconds after the RFP is connected to a power supply / PoE. After six
seconds the RFP applies the local configuration and starts using the parameters.
the switch port in the first six seconds after the RFP is connected to a power supply / PoE. After six
seconds the RFP applies the local configuration and starts using the parameters.
7.13 INSTALLING OMM IN HOST MODE
In this case, the OMM software must be installed on a PC running Red Hat Enterprise Linux 6 or
CentOS 6. The network parameters with which the OMM works in this mode depend on this PC’s
network configuration.
CentOS 6. The network parameters with which the OMM works in this mode depend on this PC’s
network configuration.
Once started, OMM works permanently on the PC. In case of fatal error or PC restart, OMM will restart
automatically.
automatically.
Please note:
Check that the versions of the OMM and RFP software on your SIP-DECT
installation are the same.
7.13.1 SYSTEM REQUIREMENTS
The OMM application is a 32-bit/x86 application that can be installed on a 32-bit or 64-bit
(recommended) operating system. The PC-based OMM requires the following configuration:
(recommended) operating system. The PC-based OMM requires the following configuration:
•
Red Hat Enterprise Linux 6 or CentOS 6 operating system
•
Server hardware minimum:
- Processor : Dual Core Intel® Xeon® 3065, 2.33GHz, 4MB cache
- Bus 1333 MHz
- Memory : 2GB DDR2 SDRAM 667 MHz
- Hard disk: 80 GB SATA 7200 rpm
- 1 GB/s Ethernet interface
7.13.2 INSTALLING THE OMM SOFTWARE
The OMM software for the Linux Redhat server is provided as a self-extracting executable file (e.g., SIP-
DECT_6.1.bin). This binary file contains two Red Hat packages:
DECT_6.1.bin). This binary file contains two Red Hat packages:
•
SIP-DECT-OMM-<SIP-DECT-version>.i586.rpm
OpenMobility Manager software.
•
SIP-DECT-HANDSET-<DECT phone-version>.i586.rpm
Software for Mitel 600 DECT phones