Firmware Version (HEX) = 41 43 52 31 32 38 31 53 20 56 31 30 33
Firmware Version (ASCII) = “ACR1281S V103”
Firmware Version (ASCII) = “ACR1281S V103”
3. Enter Firmware Upgrade Mode
Command = {
FF 00 00 E0 00
}
Response = {
FF 00 00 E1 02 90 00
}
Example:
Command:
Command:
02
6B 05 00 00 00 01 00 00 00 00
FF 00 00 E0 00
70 03
ACK:
02 00 00 03
Response:
02
83 07 00 00 00 01 00 00 00 00
FF 00 00 E1 02 90 00
09 03
Hints:
After the response display, the reader will enter the firmware upgrade mode that the reader can be
upgraded firmware.
upgraded firmware.
4. LED Control
Setting the LED State:
APDU Command = {
E0 00 00 29 01 “CMD”
}.
APDU Response = {
E1 00 00 00 01 “Status”
}
Reading the existing LED State:
APDU Command = {
E0 00 00 29 00
}.
APDU Response = {
E1 00 00 00 01 “Status”
}
CMD Bit Map
CMD
Description
Description
Bit 0
RED LED
1 = ON; 0 = OFF
Bit 1
GREEN LED
1 = ON; 0 = OFF
Bit 2
RFU
RFU
Bit 3
RFU
RFU
Bit 4
RFU
RFU
Bit 5
RFU
RFU
Bit 6
RFU
RFU
Bit 7
RFU
RFU
The “Status” bit map is the same as “CMD”.
Example: Red LED ON
Command:
Command:
02
6B 06 00 00 00 01 00 00 00 00
E0 00 00 29 01 01
A5 03
ACK:
02 00 00 03
Response:
02
83 06 00 00 00 01 00 00 81 00
E0 00 00 00 01 01
E5 03