Advanced Card Systems Limited ACR1281S ユーザーズマニュアル

ページ / 57
ACR1281S 
 
 
 Advanced Card Systems Ltd. 
Page 27 of 56 
Firmware Version (HEX) =  41 43 52 31 32 38 31 53 20 56 31 30 33   
Firmware Version (ASCII) = “ACR1281S V103” 
3. Enter Firmware Upgrade Mode 
Command = {
FF 00 00 E0 00
Response = {
FF 00 00 E1 02 90 00
Example: 
Command: 
02
 6B 05 00 00 00 01 00 00 00 00
 FF 00 00 E0 00 
70 03
 
ACK:
 
02 00 00 03  
Response: 
02
 83 07 00 00 00 01 00 00 00 00 
FF 00 00 E1 02 90 00
 
09 03
 
 
Hints: 
After the response display, the reader will enter the firmware upgrade mode that the reader can be 
upgraded firmware.
 
4.  LED Control 
 
Setting the LED State: 
APDU Command = {
E0 00 00 29 01 “CMD”
}.  
APDU Response = {
E1 00 00 00 01 “Status”
 
 
Reading the existing LED State: 
APDU Command = {
E0 00 00 29 00
}. 
APDU Response = {
E1 00 00 00 01 “Status”
 
CMD Bit Map 
CMD 
Description 
Description 
Bit 0 
RED LED 
1 = ON; 0 = OFF 
Bit 1 
GREEN LED 
1 = ON; 0 = OFF 
Bit 2 
RFU 
RFU 
Bit 3 
RFU 
RFU 
Bit 4 
RFU 
RFU 
Bit 5 
RFU 
RFU 
Bit 6 
RFU 
RFU 
Bit 7 
RFU 
RFU 
 
The “Status” bit map is the same as “CMD”. 
Example: Red LED ON 
Command: 
02
 
6B 06 00 00 00 01 00 00 00 00
 E0 00 00 29 01 01
 
A5 03
 
ACK:
 
02 00 00 03  
Response: 
02 
83 06 00 00 00 01 00 00 81 00
 
E0 00 00 00 01 01
 E5 03