Accton Wireless Broadband Corp. FIU176205T01W ユーザーズマニュアル

ページ / 112
A
PPENDIX
 C
  |  Cables and Pinouts
10/100BASE-TX Pin Assignments
–  101  –
10/100BASE-TX P
IN
 A
SSIGNMENTS
Use unshielded twisted-pair (UTP) or shielded twisted-pair (STP) cable for 
RJ-45 connections: 100-ohm Category 3 or better cable for 10 Mbps 
connections. Also be sure that the length of any twisted-pair connection 
does not exceed 100 meters (328 feet).
The RJ-45 port on the access point supports automatic MDI/MDI-X 
operation, so you can use straight-through or crossover cables for all 
network connections to PCs, switches, or hubs. In straight-through cable, 
pins 1, 2, 3, and 6, at one end of the cable, are connected straight through 
to pins 1, 2, 3, and 6 at the other end of the cable.
 
S
TRAIGHT
-T
HROUGH
 W
IRING
If the twisted-pair cable is to join two ports and only one of the ports has 
an internal crossover (MDI-X), the two pairs of wires must be straight-
through. (When auto-negotiation is enabled for any RJ-45 port on this 
switch, you can use either straight-through or crossover cable to connect 
to any device type.)
You must connect all four wire pairs as shown in the following diagram to 
support Gigabit Ethernet connections.
Table 4: 10/100BASE-TX MDI and MDI-X Port Pinouts
PIN
MDI Signal Name
a
a.
The “+” and “-” signs represent the polarity of the wires that make up each wire pair.
MDI-X Signal Name
1
Transmit Data plus (TD+)
Receive Data plus (RD+)
2
Transmit Data minus (TD-)
Receive Data minus (RD-)
3
Receive Data plus (RD+)
Transmit Data plus (TD+)
6
Receive Data minus (RD-)
Transmit Data minus (TD-)
4, 5, 7, 8
Not used
Not used