Specifications and Controls: Transmitter Unit
Code Switch: Selectable 9 pole, 3 position DIP
Frequency: 318 MHz.
Indicator Lights- Tx: Green LED: Tx Data
Mounting: (4) #6 self drilling screws included
Power Source: Batteries: 2 AA, 1.5v Alkaline or Lithium*
*Recommended for extended life in prolonged cold environments. Life expectancy: 2 yrs.
Enclosure Rating: NEMA4
Modulation: On-Off Keying
Cable Connections: Screw clamp type terminal blocks for 14-26 awg wire.
Dimensions:  MWT12: 5.62”w x  1.75”h x 1.75”d
MWTA12: 5.62”w x  2.125”h x 1.75”d
Antenna: Integral helical antenna.
Test Button: Momentary push button – Forces the transmission of the transmitter's address.
Low Battery:
Model #MWTA12 only 80-95dB Audible Alarm: Tx Alkaline battery fails below  0
:  Lithium -40
o
Transmitted Signal Duration: Approx. 3 seconds
Response Time: Nominal 70 msec; end to end
6-
Specifications and Controls: Receiver Unit
Code Switch: Selectable 9 pole, 3 position DIP
Indicator Lights - Rx:
Green LED: Power on; Red LED: Relay energized, indicates safety edge activation
Power Source: 10 to 40 VDC, 10-30 VAC (RMS)
Power Consumption: 15 mA (avg.) with Relay Off; 54 mA (avg.) with Relay On (1 Channel); (Max 128mA, 3 Ch.)
Dimensions: 4.75”w x  3.75”h x 1.25”d
Cable Connections: Integral 18” wiring with #6 spade lugs.
Maximum Operating Distance: 100 Feet
Transmitter:
FCC ID: OYE-MWT120
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATIONS IS SUBJECT TO THE FOLLOWING
TWO CONDITIONS.
1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE
AND
2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED INCLUDING INTERFERENCE THAT MAY
CAUSE UNDESIRED OPERATION.
7-
FCC Compliance
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installa-
tion. If this equipment does cause harmful interference to radio or television reception, which may be determined by turning the equip-
ment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
1- Re-orient or relocate the receiver antenna
2- Increase the separation between the equipment and the receiver
3- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
4- Consult the dealer or an experienced radio/TVtechnician for help.
Changes or Modifications Not Expressly Approved By The Party Responsible For Compliance Could Void The User’s
Authority To Operate The Equipment.
MWTA12_Inst_20130415
MWTA12_Inst_201304159D_WPE Instuctions  4/15/13  2:48 PM  Page 3