Industrial Scientific Corporation RGX ユーザーズマニュアル

ページ / 62
 
 
This equipment generates and radiates radio frequency energy during normal operation.  It could cause interference 
with other types of radio communications if not installed in accordance with the installation instructions. There is no 
guarantee that interference will not occur in a particular installation even if installed in accordance with these 
instructions. If it is determined that this equipment is causing interference to radio communications (by turning this 
equipment off and on), the interference may be corrected by one or more of the following measures: 
x  Reorient or relocate the receiving antenna. 
x  Increase the separation between the equipment and receiver. 
x  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 
x  Consult the dealer or an experienced radio/TV technician for help. 
 
This device is only compliant for use in fixed and mobile operation applications.  Install this device to maintain at least 
20 cm (8 inches) separation distance between the RGX Gateway and anywhere personnel may be present for 
prolonged periods of time to meet FCC, ISED and other international radio frequency (RF) exposure safety 
requirements. 
 
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two 
conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including 
interference that may cause undesired operation of the device. 
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. 
L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) 
l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en 
compromettre le fonctionnement. 
 
The RGX Gateway's optional Magnet Mount Kit and individual kit items can cause injury. To avoid injury, Industrial 
Scientific recommends the following.  
x  Persons with a pacemaker or implantable cardio defibrillator (ICD) should maintain a minimum separation distance 
of 90 cm (36 ″) between the pacemaker or ICD and the magnet. Please consult your physician or pacemaker or 
ICD manufacturer for additional guidance and recommendations. 
x  Neodymium magnets have a strong attractive force. Each can attract quickly when in close proximity to another 
magnet or metal surface and cause injury. The magnet material is brittle; it can crack or splinter on impact to cause 
injury and potentially become a flying hazard. Use protective gloves and eyewear to avoid a potentially severe 
pinch injury, cut, or splinter.   
x  Do not use magnet mounts with units that will draw power from a fixed DC power source.  
x  Keep magnets away from electronic devices, identification cards, and credit cards that use microchips, magnets, or 
magnetic fields. 
Certification Summary 
At the time of this document’s publication, the RGX Gateway was certified for use as summarized below. 
To determine the hazardous-area classifications for which a unit is certified, refer to its label or the 
equipment order.  
Table 0.1 RGX Gateway hazardous location certifications 
Certifying Body  
Classification
a
  
Approved temperature range 
c UL us  
Class I, Division 2, Groups A, B, C, and D, 
Temperature Class T6  
–20 °C to +55 °C (–4 °F to + 131 °F) 
a
To determine the hazardous-classified areas for which a unit is certified, refer to its label. 
 
 
Document Number: 0000037533
DO NOT CHANGE WITHOUT THE FOLLOWING AGENCY APPROVALS(S):N/A