Air4G Installation Guide
 
 
 
 
Page 11 
Commercial in Confidence 
UGD-D00229 Rev B 
national codes for electrical grounding and safety. Failure to meet safety requirements and/or use 
of non-standard practices and procedures could result in personal injury and damage to 
equipment. A direct lightning strike may cause serious damage even if these guidelines are 
followed. 
All outdoor wireless equipment is susceptible to lightning damage from a direct hit or induced 
current from a near strike. Lightning protection and grounding practices in local and national 
electrical codes serve to minimize equipment damage, service outages, and serious injury. 
Reasons for lightning damage are summarized as: 
- Poorly grounded tower/antenna sites that can conduct high lightning strike energy into 
equipment. 
- Lack of properly installed lightning protection equipment that can cause equipment failures from 
lightning induced currents. 
A lighting protection system provides a means by which the energy may enter earth without 
passing through and damaging parts of a structure. A lightning protection system does not 
prevent lightning from striking; it provides a means for controlling it and preventing damage by 
providing a low resistance path for the discharge of energy to travel safely to ground. Improperly 
grounded connections are also a source of noise that can cause sensitive equipment to 
malfunction. 
A good tower grounding system disperses most of the surge energy from a tower strike away 
from the building and equipment. 
To limit the equipment damage due to a lightning strike, the following practices are recommended 
for the wireless system: 
- Provide direct grounding from the antenna mounting bracket, the radio and antenna and the 
lightning/surge protectors to the same ground point at the base of the tower or a ground bus on 
the building. Use the grounding screws on the antenna bracket and the radio and antenna for 
terminating the ground wires. 
- The AC wall outlet ground must be connected to the same grounding system as the BS.