SmartSight Networks Inc MF24 ユーザーズマニュアル

ページ / 62

_____________________________________________________________________________________________ 
 
•  RESET SWITCH 2 (SW2) – Hardware reset 
A hardware reset can be made by momentarily pressing the SW2 switch.  This 
can be useful if the module appears not to be responding properly.    
•  RESET SWITCH 3 (SW3) – radio loader software 
RESERVED 
 
1.6  Setting the Master or Slave Mode  
 
The Microflex main electronic board integrates a two (2) position jumper to set the 
module for Master or Slave mode operation.  Refer to the illustration below for 
proper position in both modes.   
____________________________________________________________________________ 
A Multisite network must have a single Master module.  If one Microflex is set in Master 
mode, all other modules should be set in Slave mode.  The Master module should ideally be 
installed in an accessible location, typically at the base station.  The only exception to this 
is for a point-to-point video link.  In point-to-point, it is best to set the MF24-ADV in 
Master Mode and the MF24-ADVr is Slave Mode.  This allows a higher video data 
throughput (300 kbps sustained) and slightly higher quality. 
___________________________________________________________________ 
 
 
 
Figure 4 - Master and Slave mode selection 
Main Board 
Protection 
Board 
Jumper setting (master mode); Set 
jumper on two (2) upper pins for 
slave mode and two (2) lower 
pins for master mode