SmartSight Networks Inc MF24 ユーザーズマニュアル
8
_____________________________________________________________________________________________
_____________________________________________________________________________________________
• RESET SWITCH 2 (SW2) – Hardware reset
A hardware reset can be made by momentarily pressing the SW2 switch. This
can be useful if the module appears not to be responding properly.
can be useful if the module appears not to be responding properly.
• RESET SWITCH 3 (SW3) – radio loader software
RESERVED
1.6 Setting the Master or Slave Mode
The Microflex main electronic board integrates a two (2) position jumper to set the
module for Master or Slave mode operation. Refer to the illustration below for
proper position in both modes.
____________________________________________________________________________
A Multisite network must have a single Master module. If one Microflex is set in Master
mode, all other modules should be set in Slave mode. The Master module should ideally be
installed in an accessible location, typically at the base station. The only exception to this
is for a point-to-point video link. In point-to-point, it is best to set the MF24-ADV in
Master Mode and the MF24-ADVr is Slave Mode. This allows a higher video data
throughput (300 kbps sustained) and slightly higher quality.
___________________________________________________________________
mode, all other modules should be set in Slave mode. The Master module should ideally be
installed in an accessible location, typically at the base station. The only exception to this
is for a point-to-point video link. In point-to-point, it is best to set the MF24-ADV in
Master Mode and the MF24-ADVr is Slave Mode. This allows a higher video data
throughput (300 kbps sustained) and slightly higher quality.
___________________________________________________________________
Figure 4 - Master and Slave mode selection
Main Board
Protection
Board
Jumper setting (master mode); Set
jumper on two (2) upper pins for
slave mode and two (2) lower
pins for master mode
jumper on two (2) upper pins for
slave mode and two (2) lower
pins for master mode