SmartSight Networks Inc MF24 ユーザーズマニュアル

ページ / 62
  
21 
_____________________________________________________________________________________________ 
Microflex AV/ADV/AVr/ADVr North-American user’s manual / Rev 1.4 
The Microflex in master mode continuously transmits a beacon (at 10 msec 
intervals) to remote stations and this, whether or not, the data or audio port is 
active.  This beacon provides a good signal for RSSI measurement at each 
remote station. 
To conduct the remote site survey proceed as follows: 
STEP 1. 
Install the proper antenna at the remote location proposed 
 
STEP 2. 
Connect the Microflex configured as a Slave to the antenna 
 
STEP 3. 
Align the antenna to obtain maximum RSSI 
 
STEP 4. 
Note the RSSI value 
 
____________________________________________________________________________ 
If the RSSI bargraph does not reach the third LED indicator at low bit rate and the fourth 
indicator at medium bit rate, there might be insufficient margin to guarantee a 
continuous high quality link (BER > 10
-5
).  Considerable temperature variations and heavy 
rain can cause path loss variations of up to 3 dB.  There are two (2) options to decrease 
path loss: 
1) Increase the height of the base / repeater or remote antenna, or 
2) Increase the gain of the antennas used (within the 11 dBi limitation, including cable 
losses).  
If these options are not feasible, a repeater station may have to be installed strategically 
along the path. 
____________________________________________________________________________ 
 
 
3.1.5  RF Exposure Considerations 
 
In order to comply with the RF exposure requirements of CFR47 1.1310, the 
S1000 must be installed in such a way as to allow a minimum separation distance 
of 10 cm (4 in.) between antennas and persons nearby.