123 
 
Current: 10Adc 
Insertion Loss: 
≤ 0.25dB 
Freq. Range: 
0-2400MHz 
Mounting: Bulkhead 
Operating Voltage: 
+/-60 Volts 
Protected Side Connector: 
N Female 50
Ω 
Replaceable Gas Tube: 
Yes 
Surge Side Connector: 
N Female 50
Ω 
Throughput Energy: 
≤ 2283µJ for 3kA @ 8/20µs Waveform 
Turn-On Voltage: 
+/-180 Volts 
Unit Impedance: 
50
Ω 
Voltage Standing Wave Ratio: 
1.28 : 1 
Weatherized: Bellcore 
#TA-NWT-000487 Procedure 4.11,  
Wind Driven (120 mph) Rain Intrusion. 
 
8.5.6 
RF Feed Throughs (N-type connectors) 
 
514-0001-99 
Terminator, N-M w/ chain 2W 6GHz, 18db max VSWR @ 6GHz 
S.M Electronics P/N:  STN0610C 
8.6  Available Field Replaceable Units (FRUs) 
The MC-Series System has been designed so that Field Repairable Units (FRUs) can be 
replaced to restore normal system operation as quickly as possible. The following table lists 
RadioFrame Networks FRUs. For equipment not supplied by RadioFrame Networks, follow 
standard Nextel policies and procedures for FRU replacement. For more information, refer to 
section 1.4.3 Field Replaceable Unit (FRU) Policy. 
Table 7 
MC-Series System FRUs 
P/N 
Description 
176-0840-xx 
800 MHz MC Series iDEN 2-Port RadioBlade (RB) Transceiver 
176-0870-xx 
800 MHz RF Shelf 
176-0535-xx 
RadioBlade Transceiver Shelf (RBS)