BodyMedia Inc. 185 ユーザーズマニュアル

ページ / 15
BodyMedia FIT Armband BW Manual
BodyMedia FIT Armband BW Manual
For troubleshooting information and additional resources, please refer to the Help 
section on www.bodymedia.com. 
Troubleshooting
Product Specifications
Armband
• Sensors:
         
• Accelerometer (3-axis)
         
• Heat Flux
         
• Skin Temperature 
         
• Galvanic Skin Response (GSR)
• Materials:
         
• Armband: ABS, polycarbonate, thermoplastic polyurethane, 304 grade stainless steel
         
• Adjustable strap/wing assembly: Nylon, polyester, Lycra (no latex content) or 
             polyisoprene, polycarbonate, thermoplastic polyurethane, silicone
• Battery power: Model AB185:  about 2-4 days under steady use
• Battery type: Internal lithium polymer cell battery
• Radio Frequency: 2.4GHz
• Model AB185 contains a class 2 Bluetooth® wireless technology transceiver
• Transmitter output power: Model AB185:  <2.5mW
• Memory capacity: about 14 days under steady use for Model AB185 
• Armband size: (l) 55mm x (w) 62mm x (h) 13mm [2.2” x 2.4” x 0.5”]
• Armband weight (with adjustable strap):  45.4g (1.6oz)
• Water resistance: IP64 classified (only when Armband is properly inserted into the Armband 
strap)
• Operating temperature/humidity: 5°C - +40°C (40°F to 104°F)/ 5 - 95% RH non-condensing
• Storage temperature/humidity: -20°C - +60°C (-4°F to 140°F) / 5 - 95% RH non-condensing.
16
17
Accuracy
Accelerometer (3-axis)
Calibrated range is +/- 1.0g
Minimum resolution is 0.01g
Two-standard-deviation error of  
+/-0.08g on all axes 
Heat Flux 
Calibrated Range is 0.0 W/m
to     
300.0 W/m
A minimum resolution of 1.0 W/m
Two-standard-deviation error of           
+/-10.0 W/m
2, 
0 to 30 W/m
2
Two-standard-deviation error of           
+/-35.0% otherwise
Galvanic Skin Response 
Calibrated Range is 56 kOhms to 
20 MOhms (50.0 nSiemens  – 17.0 
µSiemens)
Two-standard-deviation error of +/- 9.0 
nSiemen. 50 to 225 nSiemens
         Two-standard-deviation error of +/-
         4.0% otherwise
 
 
Skin Temperature 
Calibrated Range is 20.0ºC to 40.0ºC
A minimum resolution of 0.05ºC
Two standard deviation error of +/- 
0.8°C 
System (Per day, adults)
Total calories/METs for free living  
activities: mean error < 10%
Total minutes of physical activity:    
mean error < 5%
Total step count: mean error < 9%