4.3.- STARTING UP 
 
Proceed with caution; the equipment may not be connected correctly 
which may lead to unforeseeable movements on starting-up. 
Once the receiver has been connected, disconnect the power supply to the motors, (for 
example, by removing the fuses) and power on the receiver. With this, the receiver will 
enter into a ‘SCANNING’ mode and the following LED’s will be lit in the receiver; 
POWER:  ON, indicates that the power supply is correct. 
HARDOK:  ON, indicates the absence of faults on the boards. 
SIGNAL:  OFF in the case of the channels being signal free. Blinks ON when 
there is a RF signal on the channels 
DATA: 
OFF; when there is not another TM70 system active in the area. 
Blinks ON in the opposite case.. 
ID:  
OFF 
Next, turn transmitter ON to OPERATION mode, as follows: 
 
Place a charged battery in the transmitter. 
 
Turn the contact key. 
 
Push and pull out the STOP button. LED flashes once orange and then green for 3 
seconds. If the transmitter has LCD, it displays the identification of the machine, as 
well as the battery level. 
 
Press the start button. The green LED should now light indicating that the 
transmitter is transmitting. 
 
   
 
 
   
 
1.- Label for crane identification.  
Optional: LCD Display 
2.- LED. 
3.- Manoeuvre button 
4.- Contact key  
5.- Start button 
6.-  STOP button  
7.- Option: Range Limitation 
 
 
 