Wilson Electronics LLC 272770 ユーザーズマニュアル

ページ / 16
AIG #111089_Rev1_07 .31 .12
Signal Booster Specifications
 
 
Tri-Band AWS
Model Number
272770
Antenna connectors
N-Female
Antenna impedance
50 Ohms
Dimensions
8 .875 x 6 .0 x 1 .5 inch (22 .5 x 15 .2 x 3 .8 cm)
Weight
2 .8 lbs (1 .270 kg)
Frequency
1710-2155 MHz / 824-894 MHz / 1850-1990 MHz
1
Passband Gain (nominal)
1700-2100 MHz
(Typical / Maximum)
800 MHz
(Typical / Maximum)
1900 MHz
(Typical / Maximum)
Uplink 
Downlink
70 dB / 77 dB
65 dB / 72 dB
69 dB / 77 dB
69 dB / 76 dB
70 dB / 77 dB
71 dB / 78 dB
2
20 dB Bandwidth (nominal)
1700-2100 MHz
(Typical / Maximum)
800 MHz
(Typical / Maximum)
1900 MHz
(Typical / Maximum)
Uplink 
Downlink
78 MHz / 87 MHz
85 MHz / 94 MHz
40 MHz / 45 MHz
38 MHz / 42 MHz
71 MHz / 79 MHz
77 MHz / 85 MHz
3
Power output for single cell phone (uplink) dBm
1700 MHz
800 MHz
1900 MHz
30 .45
33 .65
30 .54
3
Power output for single cell phone (downlink) dBm
2100 MHz
800 MHz
1900 MHz
21 .26
23 .76
20 .67
4
Power output for multiple received signals 
(uplink) dBm
Maximum Power
The maximum power is reduced 
by the number of signals:
Number of signals
1700 MHz
800 MHz
1900 MHz
2
20 .8
24 .5
22 .7
3
17 .3
20 .9
19 .2
4
14 .8
18 .4
16 .7
5
12 .8
16 .5
14 .8
6
11 .2
14 .9
13 .2
4
Power output for multiple received signals 
(downlink) dBm
Maximum Power
The maximum power is reduced 
by the number of signals:
Number of signals
2100 MHz
800 MHz
1900 MHz
2
20 .1
24 .6
22 .3
3
16 .5
21 .1
18 .8
4
14 .0
18 .6
16 .3
5
12 .1
16 .7
14 .3
6
10 .5
15 .1
12 .7
Noise Figure (typical downlink/uplink)
4 dB nominal 
Isolation
> 90 dB
Power Requirements
6 V, 1 .5 A - 3 .0 A
Notes:
1 . Nominal gain is the maximum gain at any frequency in the passband .
2 . Nominal bandwidth is the difference between two frequencies that are adjacent to the passband where the amplification is 20 dB lower than the passband amplification . One of the frequencies is lower than the   
  passband and the other is higher .
3 . The Manufacturer’s rated output power of this equipment is for single carrier operation .  For situations when multiple carrier signals are present, the rating would have to be reduced by 3 .5 dB, especially where the  
  output signal is re-radiated and can cause interference to adjacent band users .  This power reduction is to be by means of input power or gain reduction and not by an attenuator at the output of the device .
4 . The maximum power for 2 or more simultaneous signals will be reduced by 6 dB every time the number of signals is doubled .
3301 East Deseret Drive, St . George, UT 84790
For additional Technical Support visit  www .WilsonElectronics .com 
or email at: tech@wilsonelectronics .com
Phone: 866-294-1660    Local: 435-673-5021    Fax: 435-656-2432
www .twitter .com/WilsonCellular      www .facebook .com/WilsonCellular