Wilson Electronics LLC 277180 ユーザーズマニュアル

ページ / 20
Signal Booster Specifications
FCC ID: PW0277180
IC: 4726A-277180
Channelized 800
Model Number
277180
Antenna connectors
N Type
Antenna impedance
50 Ohms
Dimensions
5 .7 x 4 .2 x 1 .5 inch (14 .0 x 10 .8 x 3 .9 cm)
Weight
1 .27 lbs (0 .544 kg)
Frequency
824-890 MHz
1
Channels Passband Gain (nominal)
800 MHz 
70 dB Typical,  
75 dB Maximum
2
20 dB Bandwidth (nominal)
Downlink
800 MHz
12 MHz
Power Output
800 MHz
Power output for single cell phone (uplink)
29 .8 dBm
Power output for single received channel (downlink)
29 .8 dBm
3
Power output for multiple transmitted channels 
(uplink)
Maximum Power
The maximum power is reduced 
by the number of channels:
Number of channels
800 MHz
2
23 .3 dBm
3
18 .3 dBm
4
17 .2 dBm
5
15 .3 dBm
6
13 .7 dBm
4
Power output for multiple received channels 
(downlink)
Maximum Power
The maximum power is reduced 
by the number of channels:
Number of channels
800 MHz
2
24 .1 dBm
3
18 .3 dBm
4
18 .1 dBm
5
16 .2 dBm
6
14 .6 dBm
Noise Figure (typical downlink/uplink)
3 .5 dB nominal 
Isolation
> 90 dB
Power Requirements
110-240 V AC, 50-60 Hz, 15 W
3301 East Deseret Drive, St . George, UT 84790
For additional Technical Support visit  www .WilsonElectronics .com 
or email at: tech@wilsonelectronics .com
Phone: 866-294-1660    Local: 435-673-5021    Fax: 435-656-2432
www .twitter .com/WilsonCellular      www .facebook .com/WilsonCellular
AIG #110980 - RevP - 11 .17 .11
Notes:
Nominal gain is the maximum gain at any frequency in the passband .
1 . 
Nominal bandwidth is the difference between two frequencies that are adjacent to the passband where the amplification is 20 dB lower than the 
2 . 
passband amplification . One of the frequencies is lower than the passband and the other is higher .
The Manufacturer’s rated output power of this equipment is for single carrier operation .  For situations when multiple carrier signals are present, the 
3 . 
rating would have to be reduced by 3 .5 dB, especially where the output signal is re-radiated and can cause interference to adjacent band users .  This 
power reduction is to be by means of input power or gain reduction and not by an attenuator at the output of the device .
The maximum power for 2 or more simultaneous signals will be reduced by 6 dB every time the number of signals is doubled .
4 .