6.2  TROUBLESHOOTING 
Following installation and commissioning, occasional operation tasks to handle alarms may be required: 
 
Table 16: MU Alarms Diagnosis 
Alarm condition 
Diagnosis 
Over- 
Temperature 
alarm 
 
Check device temperature on WEB GUI 
 
If device temperature is over threshold, make sure environment temperature is 
within the envireonment temperature range that MU supported (0~40
℃). Apply 
climatic protection to the system under severe environment. 
Optical TX Alarm 
 
Test MU transmit optical power  
 
Replace FOU if transmit optical power is less than -7dBm 
Optical RX Alarm 
 
Use Optical Power Meter to test received optical power 
 
If received optical power is lower than -10dBm, test whether RU transmit optical 
power is normal (3~5dBm) 
 
Check if optical loss of fiber link is higher than 6.5dBo 
 
Clean fiber connector with absolute ethanol
 
 
DL Input Power 
Overload Alarm  
Test  DL  input  power  of  MU,  if  it  is  higher  than  +33dBm,  choose  proper  coupler  to 
ensure the input power to MU is lower than +33dBm. 
 
Table 17: RU Alarms Diagnosis 
Alarm condition 
Diagnosis 
External Alarm  
Check to make sure if the external device connected is working normally 
Over- 
Temperature 
alarm 
 
Check device temperature on WEB GUI 
 
If device temperature e is over threshold, make sure environment temperature is 
within the envireonment temperature range that RU supported (-20~50
℃).Apply 
climatic protection to the system under severe environment. 
Optical TX Alarm 
 
Test RU transmit optical power  
 
Replace FOU if transit optical power is less than 0dBm 
Optical RX Alarm 
 
Use Optical Power Meter to test received optical power 
 
If received optical power is lower than -14dBm, test whether MU transmit optical 
power is normal (-4~-2dBm) 
 
Check if optical loss of fiber link is higher than 6.5dBo 
 
Clean fiber connector with absolute ethanol
 
 
DL PA alarms  
Check PA Service Status on WEB GUI RU page,  
 
If it is [Recovery], reset PA on WEB GUI Management page, then read RU 
output power: If output power is exceed threshold, need to reduce gain or input 
power; if output power is normall, check whether antenna port VSWR is too high. 
 
If it is [Shutdown], Refer to PA Shutdown Alram 
DL Output Power 
Overload Alarm 
 
Check if output power is exceed the threshold (32dBm for LRU, 39dBm for MRU) 
 
Decrease the gain to reduce the output power 
PA Shutdown 
Alarm 
 
Make Sure the environment temperature is -20~50
℃ 
 
Reset PA, if PA service status turns to [Recovery], and then refer to DL PA 
Alarms. If PA still shutdown, the PA module maybe damaged, please contact 
with Comba to replace the RU. 
LNA Alarm 
Uplink LNA modual damaged, please contact with Comba to replace the RU.  
 
End of Section