Maxon Electronics Australia Pty. Ltd. MM-5100P ユーザーズマニュアル
FCC Documentation
Feb. 12, 2003
25/25
Maxon Proprietary : Restricted Distribution
.
This document is the sole and exclusive property of Maxon
Australia. Not to be distributed or divulged without prior written agreement.
Maxon Electronics Australia Pty. Ltd. 36A Gibson Avenue, Padstow, N.S.W. Australia
Tel : +61 2 9707-2000 Facsimile : +61 2 9707-3328 URL : http//www.maxon.com.au
Tel : +61 2 9707-2000 Facsimile : +61 2 9707-3328 URL : http//www.maxon.com.au
RFT3100.
The transmitter IF VCO is set to 267.2 MHz by an external varactor-tuned resonant tank circuit. An
internal phase-lock loop and external loop filter network provides the feedback to the varactor that
tune the VCO precisely to 267.2 MHz. A master-slave divide-by-two circuit generates I and Q signals
in precise quadrature for the mixers.
Figure 8-2 IFR3300 and RFT3100 Functional Block Diagram