7  Electrical Specifications 
7.1  Electrical Characteristics 
Conditions: Operating voltage 3.0V unless otherwise specified 
  
 
 
 
 
 
The ESL is in sleep mode almost the entire time. The device wakes up at regular intervals 
(called the poll time) and it then transmits a poll request to the base station. When the base 
station has no data to send, it acknowledges the poll after which the ESL immediately goes 
back to sleep. The minimum poll rate is configurable and is set to 20 seconds by default.  A 
higher poll rate will decrease the power consumption but will increase the response time. 
 
7.2  Battery 
The power is supplied to the ESL by 2 CR2450 batteries:  
• Nominal capacity: 1200 mAh (two times 600mAh) 
• Nominal voltage: 3.0 V.  
• Maximum self-discharge rate: <1% per year 
• Usable time: 7 years minimum (Update frequency: 4 times per day, poll time 20 seconds)  
 
 
The operating time of the batteries is based on any of the following factors that influence the 
battery life: 
 
Factor 
Default values and  
estimated averages 
Correlation * 
(Higher is better) 
Influence 
Polling for data & 
reporting settings 
Interval: 20 seconds 
Retransmissions: 10% 
Report ratio: 1 to 39  
Yes 
No 
Yes 
61% 
Display updates 
4 updates per day 
Temperature: 15-25° C 
No 
No 
20% 
Out of range /  
base station OFF % 
Not connected: 2% 
Number of channels: 5 
No 
No 
4% 
Sleep time 
99,9% 
Yes
 
9% 
Battery self-discharge 
1 % / year 
No
 
6% 
 
* The correlation shows whether increasing the listed value increases or decreases the power 
consumption of the ESLs.  
 
For example: 
• Increasing the poll interval lowers the power consumption 
• Turning off the base stations increases the power consumption 
• A lower operating temperature increases the power consumption 
• More display updates per day increase the power consumption 
 
Parameter 
Typ 
Unit 
Remarks 
Operating voltage 
2.3-3.3  
Lithium primary battery 
Sleep current 
2-5 
µA 
When the transmitter and receiver are idle 
Poll time 
>= 20 
seconds 
See below