GENERAL INFORMATION
Product Description for Equipment under Test (EUT)
The CANEL LIGHTING CO., LTD.’s model: E26 Series: MAE-SP-10WL (D), MAE-SP-15WL (D),
MAE-SP-20WL (D), MAE-SP-25WL (D), GU10 Series: MAE-SG-10WL (D), MAE-SG-15WL (D),
MAE-SG-20WL (D), MAE-SG-25WL (D), UB Series: MAE-UB-10WL (D), MAE-UB-15WL (D), or the
“EUT” as referred to in this report is a ENERGY SAVING LAMPS which measures approximately
10W: 115.0
cm L x
44.5 cm W,
15W:
120.0
cm L x 44.5 cm W,
20W:
125.0
cm L x 52.0 cm W,
25W:
145.0
cm L x 52.0 cm W,
rated input voltage: AC 120V/60Hz.
*
*
The test data gathered are from production sample, serial number: 0606006. Provided by the manufacturer, we
received EUT on 2006-06-30.
Objective
The following test report is prepared on behalf of CANEL LIGHTING CO., LTD. in accordance with Part 2,
Subpart J, and Part 18, Subparts A, B and C of the Federal Communication Commissions rules and
regulations.
The objective of the manufacturer is to determine compliance with FCC Part 18 limits.
Related Submittal(s)/Grant(s)
No related submittal(s).
Test Methodology
All measurements contained in this report were conducted with MP-5, FCC Methods of Measurements of
Radio Noise Emissions from ISM Equipment, February 1986. All measurements were performed at Bay
Area Compliance Lab Corp. (ShenZhen). The radiated testing was performed at an antenna-to-EUT
distance of 3 meters.
Radio Noise Emissions from ISM Equipment, February 1986. All measurements were performed at Bay
Area Compliance Lab Corp. (ShenZhen). The radiated testing was performed at an antenna-to-EUT
distance of 3 meters.
Test Facility
The Test site used by Bay Area Compliance Lab Corp. (ShenZhen) to collect radiated and conducted
emission measurement data is located in the 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road,
FuTian Free Trade Zone, ShenZhen, GuangDong 518038, P.R.China.
Test site at Bay Area Compliance Lab Corp. (ShenZhen) has been fully described in reports submitted to
the Federal Communication Commission (FCC). The details of these reports have been found to be in
compliance with the requirements of Section 2.948 of the FCC Rules on November 04, 2004. The facility
also complies with the radiated and AC Live conducted test site criteria set forth in ANSI C63.4-2003 and
FCC MP-5.
The Federal Communications Commission has the reports on file and is listed under FCC Registration No.:
382179. The test site has been approved by the FCC for public use and is listed in the FCC Public Access
Link (PAL) database.