Canel Lighting Co. Ltd. CANEL868 Internal Photos
CANEL LIGHTING CO., LTD. FCC ID: Q3CCANEL868
Report # RSZ06063082
Page 7 of 23
FCC Part 18 Report
EMI Test Receiver Setup
The EMI test receiver was set to investigate the spectrum from 450 kHz to 30 MHz.
During the conducted emission test, the EMI test receiver was set with the following configurations:
Frequency Range
IFBW
450 kHz – 30 MHz 9 kHz
Test Equipment List and Details
Manufacturer
Description
Model
Serial Number
Calibration
Date
Calibration
Due Date
Com-Power L.I.S.N.
LI-200
12005 N/A N/A
Com-Power L.I.S.N.
LI-200
12008 N/A N/A
Rohde &
Schwarz
EMI Test Receiver
ESCI
100028
2005-8-17
2006-8-17
Rohde &
Schwarz
L.I.S.N. ESH2-Z5
892107/021
2006-2-28
2007-2-28
* Com-Power’s LISN were used as the supporting equipment.
* Statement of Traceability:
Bay Area Compliance Lab Corp. (ShenZhen) attests
that all calibrations have
been performed in accordance to NVLAP requirements, traceable to the NIST.
Test Procedure
During the conducted emission test, the EUT power cord was connected to the outlet of the LISN.
Maximizing procedure were performed on the six (6) highest emissions of the EUT.
All data was recorded in the Quasi-peak detection mode.