Canel Lighting Co. Ltd. CANEL868 Internal Photos

ページ / 23
CANEL LIGHTING CO., LTD.                                                                            FCC ID: Q3CCANEL868 
Report # RSZ06063082 
  Page 7 of 23 
               FCC Part 18 Report 
 
EMI Test Receiver Setup 
 
The EMI test receiver was set to investigate the spectrum from 450 kHz to 30 MHz. 
 
During the conducted emission test, the EMI test receiver was set with the following configurations: 
 
Frequency Range 
IFBW 
450 kHz – 30 MHz               9 kHz    
 
 
Test Equipment List and Details 
 
Manufacturer 
Description 
Model 
Serial Number 
Calibration 
Date 
Calibration 
Due Date 
Com-Power L.I.S.N. 
LI-200 
12005  N/A  N/A 
Com-Power L.I.S.N. 
LI-200 
12008  N/A  N/A 
Rohde & 
Schwarz 
EMI Test Receiver 
ESCI 
100028 
2005-8-17 
2006-8-17
Rohde & 
Schwarz 
L.I.S.N. ESH2-Z5 
892107/021 
2006-2-28 
2007-2-28
 
Com-Power’s LISN were used as the supporting equipment. 
* Statement of Traceability: 
Bay Area Compliance Lab Corp. (ShenZhen) attests
 that all calibrations have 
been performed in accordance to NVLAP requirements, traceable to the NIST. 
 
 
Test Procedure 
 
During the conducted emission test, the EUT power cord was connected to the outlet of the LISN. 
 
Maximizing procedure were performed on the six (6) highest emissions of the EUT. 
 
All data was recorded in the Quasi-peak detection mode.