AeroScout EX4200 Ultrasound Exciter 
 
Connecting the Exciter to the Network and Power Source    
11 
Usage option 
Description 
Single Exciter with External 
LF Antenna unit 
There is an option to connect an External LF 
Antenna unit to the EX4200 Exciter. The 
External LF Antenna unit should be mounted 
outside the room, next to the door. It should be 
configured to turn off the ultrasound receiver 
of the T2u Tag. 
Power Supply Options 
The various power supply options for powering up the Exciter are described below. 
Direct Power Supply 
Directly connect a 48VDC power source to the Exciter’s power jack (connector 2 in 
Figure 2).  
 
Note
 
An Exciter requires approximately 10W of power. When connecting an Exciter 
to a direct power source with one of the above voltage levels, verify that the 
current level is sufficient. 
When using a direct power source for chained Exciters, you can drive power 
to no more than three Exciters sequentially even if the source power is 
sufficient for more.  
Unit shall be powered only by limited power source (marked LPS or NEC 
class 2) power supply. 
 
PoE Switch 
If your network has a Power-over-Ethernet infrastructure, you can connect a CAT-5 
Ethernet cable from the PoE switch to the Exciter’s LAN connector (connector 1 in 
Figure 2). This supplies both the power and the network connection.  
 
Note
 
PoE standard 802.3af class 0 allows power for not more than one Exciter. 
When using PoE with chained Exciters, a PoE connection must be made to 
every single Exciter in the chain. In addition, the LAN connectivity that the 
PoE supplies will not be utilized for slave Exciters in a chain.