AeroScout ANT4200 ユーザーズマニュアル
AeroScout EX4200 Ultrasound Exciter
Chaining Exciters
14
Chaining Exciters
In an area where the required LF coverage exceeds the capacity of one Exciter, you
can chain up to three Exciters, thus extending the coverage area. For example, a large
entrance gate for trucks and heavy equipment that is 30m wide might require three
Exciters chained to one another. This solution is relevant for LF transmissions only.
can chain up to three Exciters, thus extending the coverage area. For example, a large
entrance gate for trucks and heavy equipment that is 30m wide might require three
Exciters chained to one another. This solution is relevant for LF transmissions only.
Exciter EX4200 can be chained to either another Exciter EX4200 or to an Exciter
EX3210.
EX3210.
The chained Exciters are treated by the system as a single entity. Their transmissions
do not interfere with one another.
do not interfere with one another.
Note
The Exciters’ transmission ranges and physical position should be set in a
manner that will allow overlapping between neighboring Exciters’ coverage
areas.
manner that will allow overlapping between neighboring Exciters’ coverage
areas.
Figure 6 illustrates chained Exciters and shows the connections.
Figure 7: Exciter chaining
Chain Connection
Up to 3 Exciters can be connected to each other in a chain, as follows:
1. The first Exciter in the chain that’s directly connected to the LAN is called the
“master”. The others are called “slave”. Any EX4200 can be master.
2. The master is connected to the next slave from the master’s OUT connector
(connector 4 3 in Figure 2) to the slave’s IN connector (connector 3 in Figure 2).