For  information  about  the  deployment  and  configuration  of  GPS  Gateway  for  T6 
Tags, please refer to MobileView Installation and Deployment Guide      
Tag Maintenance 
Upgrading the Firmware 
The  AeroScout  T6  Tag’s  firmware  too  can  be  upgraded  automatically  through  the 
Wi-Fi network. 
This  is  done  by  sending  the  upgrade  to  all  tags  found  in  the  site,  through  the 
AeroScout Bidirectional Tag Controller application. In this case too, tags receive the 
update when they associate with the network. 
Replacing the Internal Batteries 
The  AeroScout  Tag  uses  a  battery  pack  consisting  of  two  3.6V  Lithium-Thionyl 
Chloride  (Li-SOCl2)  batteries,  with  38  AH  capacity.  The  life  expectancy  of  the 
batteries  depends  on  the  tag’s  configuration.  For  example,  shorter  transmission 
intervals  and  a  higher  number  of  network  associations  per  day  consume  more 
energy.