The Monitor Log
 Chapter 7
RADWIN 1000/2000/5000 User ManualVersion  2.5.30p3
7-8
Table 7-3: Explanation of performance data
Data type
Reported Value
Explanation
Generic PM Data
UAS – Unavailable 
Seconds
Seconds in which the interface was out of service.
ES – Errored Sec-
onds
The number of seconds in which there was at least 
one error block. Note that the notation of an error 
block is different per interface.
SES – Severe Errored 
Seconds
The number of seconds in which the service quality 
was low (the quality is different per type of inter-
face and determined by the BBER threshold per 
interface).
BBE – Background 
Block Error
The number of errored blocks in an interval.
Integrity
A flag indicating that the data was valid. Note that 
the Performance Monitoring data is not valid if not 
all the values were stored (e.g., due to clock 
changes within the interval or power up reset).
Air Interface PM 
Data
Max RSL
The maximum of the receive signal level (mea-
sured in dBm).
Min RSL
The minimum of the receive signal level (measured 
in dBm).
Max TSL
The maximum of the transmit signal level (mea-
sured in dBm).
Min TSL
The minimum of the transmit signal level (mea-
sured in dBm).
RSL Threshold 1
The number of seconds in which the RSL was 
below the specified threshold.
RSL Threshold 2
The number of seconds in which the RSL was 
below the specified threshold.
TSL Threshold
The number of seconds in which the RSL was 
above the specified threshold.
BBER Threshold
The BBER Threshold value counts the number of 
seconds in which the Background Block Error Ratio 
(BBER) exceeded the specified threshold. 
Ethernet Interface 
PM Data
Received Bytes
The number of Megabytes received at the specified 
port within the interval
Transmitted Bytes
The number of Megabytes transmitted at the spec-
ified port within the interval.