Radwin Ltd. RW2058 ユーザーズマニュアル

ページ / 211
RADWIN Manager Traps
Appendix F
RADWIN 1000/2000/5000 User ManualVersion  2.5.30p3
F-21
RADWIN Manager Traps
The RADWIN Manager application issues traps to indicate various events. 
These traps are shown in the RADWIN Managerr Events Log.
A list of Trap Messages as displayed by the RADWIN Manager is shown in 
changeLinkPasswordClear
204
normal
Indicates that the Link Password was changed successfully. Contains a 
single parameter which is its description: 1 - Description: Link Password 
has been changed at/on: %s. %s - Is the Local Site name or Remote Site 
name or both sides of the Link. 
externalAlarmInPort1Clear
204
normal
This Trap is sent every time an External Alarm Input fault of port # 1 is 
cleared. Contains a single parameter which is its description: 1 - 
Description: External Alarm 1 - <User Text> - Alarm Cleared. 
externalAlarmInPort2Clear
206
normal
This Trap is sent every time an External Alarm Input fault of port # 2 is 
cleared. Contains a single parameter which is its description: 1 - 
Description: External Alarm 2 - <User Text> - Alarm Cleared. 
lanPort1Clear
209
normal
Indicates the LAN port 1 status changed to connected. Contains two 
parameters: 1 - Description: LAN port 1 status changed to connected - 
%s. 2 - %s Is the Eth. mode (speed & duplex). 
lanPort2Clear
210
normal
Indicates the LAN port 2 status changed to connected. Contains two 
parameters: 1 - Description: LAN port 2 status changed to connected - 
%s. 2 - %s Is the Eth. mode (speed & duplex). 
mngPort2Clear
211
normal
Indicates the management port status changed to connected. Contains 
two parameters: 1 - Description: Management port status changed to 
connected - %s. 2 - %s Is the Eth. mode (speed & duplex). 
externalAlarmInPort3Clear
211
normal
This Trap is sent every time an External Alarm Input fault of port # 3 is 
cleared. Contains a single parameter which is its description: 1 - 
Description: External Alarm 3 - <User Text> - Alarm Cleared. 
externalAlarmInPort4Clear
213
normal
This Trap is sent every time an External Alarm Input fault of port # 4 is 
cleared. Contains a single parameter which is its description: 1 - 
Description: External Alarm 4 - <User Text> - Alarm Cleared. 
swVersionsMatchFullCompatibilityClear
214
normal
The trap is sent in case SW versions match. Contains a single parameter 
which is its description: 1 - Description: Software Versions compatible 
swVersionsMatchRestrictedCompatibilityClear
215
normal
The trap is sent in case SW versions match and link functionality is not 
restricted. Contains a single parameter which is its description: 1 - 
Description: Software Versions compatible 
swVersionsMatchSoftwareUpgradeRequiredClear
216
normal
The trap is sent in case SW versions match and SW upgrade is 
successful. Contains a single parameter which is its description: 1 - 
Description: Software Versions compatible 
swVersionsCompatibleClear
217
normal
The trap is sent in case SW versions compatible Contains a single 
parameter which is its description: 1 - Description: Software Versions 
compatible 
tdmBackupClear
221
normal
linkLockAutorizedODU
223
normal
Indicates that the ODU is autorized.   Contains a single parameter  which 
is its description:   1 - Description: Authorized ODU connection permitted.
linkAuthenticationDisabled
224
normal
Indicates that the Link Lock is disabled.   Contains a single parameter  
which is its description:   1 - Description: Link Authentication has been 
disabled
Table F-3: MIB Traps (Sheet 4 of 4)
Name
ID
Severity
Description