Fiber Optic RF Repeater System
Figure 2. Fiber Transceiver Unit User Alarms and Control Interface (FS31LM-01-
LMC)
The user alarms and controls are organized by link type. The Optical in / RF out section is
for the uplink optical receivers and the RF in / Optical out section if for the downlink optical
transmitters. For uplink optical receivers, each receiver has a gain control that is accessed
using a small standard screwdriver.
for the uplink optical receivers and the RF in / Optical out section if for the downlink optical
transmitters. For uplink optical receivers, each receiver has a gain control that is accessed
using a small standard screwdriver.
The Opt in Alarm interface uses a wire contact header (supplied) that will plug into
the Opt in Alarm sockets. Connection of alarm wires to the wire contact header
requires a small standard flathead screwdriver. The Optical In alarm LED on the
right side of the alarm header indicates an alarm condition for each individual uplink
optical receiver.
For Downlink optical transmitters, each Opt in Alarm interface uses a wire contact
header (supplied) that will plug into the Opt in Alarm sockets. Connection of alarm
wires to the wire contact header requires a small standard screwdriver. The alarm
LED on the right side of the alarm header indicates an alarm condition for each
individual downlink optical transmitter.
Connect fiber optic cables last. Use fiber optic connector cleaning precautions to
get the highest performance from the system. Do not make optical connector tip
contact with any hard surface. Be sure the FC/APC KEY is aligned before
tightening. Do not over tighten.
5.3 FS31HM-85-C-18-65,
Optical Repeater Unit (ORU)
Also known as BDA.
Below is a diagram of the inside of the ORU.