Troubleshooting and Maintenance
Onboard Diagnostics
The ViVOpay 8100 has a built-in diagnostics program accessible through the RS-232 interface. If you 
did not purchase an RS-232 data cable with your ViVOpay 8100, you will need one to access the 
diagnositic tests. The Onboard Diagnostics (OBD) tests the following components of the ViVOpay 
8100.
Accessing the OBD Tests
To connect the ViVOpay 8100 to a terminal emulator
1. Connected the RS-232 data cable to the ViVOpay 8100 as described in 
.
2. Launch the terminal emulation program and set the serial communication parameter of 
the terminal emulation program to the following:
Baud rate: 11500
Parity: none
Stop bit: 8
Flow control: none
3. Connect the BD-9 end of the data cable to the COM port of a computer running a terminal 
emulation program.
To enter the Onboard Diagnostics
1. Power off the ViVOpay 8100 by removing the power supply from the power receptacle.
2. Plug the power supply back into the power receptacle.
3. Press the 3 key and hold it down until the the main ViVOpay AR Diagnostics screen 
appears. This is approximately 40 seconds after power is first applied.
Test
Possible Results
LCD Test
Pass/Fail
Touch Screen Test
Pass/Fail. This test is not valid for the ViVOpay 8100.
Key Test
Pass/Fail 1234567890<cancel><backspace><enter>
LED Test
Pass/Fail
Buzzer Test
Pass/Fail
Magstripe Test
Pass Tracks 1 or 2 or 3/Fail
RFID Test
Pass Type A or B/Fail
Security Keys Test
KPK, DUKPT, Master 1234567890
ViVOpay AR Diagnostics
1  Onboard Diagnostic
2  
3  Application Tests
4  Get Version
5  Boot
X  Exit