KROHNE FMCW06G10 ユーザーズマニュアル

ページ / 76
3
 INSTALLATION 
22 
OPTIWAVE 1010
www.krohne.com
09/2014 - 4003537401 - MA OPTIWAVE 1010 R01 en
Installation in tanks containing one liquid or more without foam
•  Drill an air circulation hole (max. Ø10 mm / 0.4¨)  in the stilling well above the maximum level.
•  Drill 1 or more liquid circulation holes in the stilling well (if there is more than 1 liquid in the 
tank).
i
These holes help the liquid to move freely between the stilling well and the tank.
•   Remove the burr from the hole.
3.9  How to attach the weather protection to the device
The device and the weather protection option are supplied disassambled in the same box. You 
must attach the weather protection when you install the device.
The overall dimensions of the weather protection are.
Figure 3-7: Equipment needed
1  Device
2  Weather protection (option).
3  2 butterfly screws and spring washers. The manufacturer attaches these parts to the device before delivery.