OPERATION
48
OPTIWAVE 7500 C
www.krohne.com
10/2016 - 4004375401 - MA OPTIWAVE 7500 R01 en
If your security level is too low, the display will show a "lock" symbol adjacent to menu items in
Program mode. If it is necessary to change this setting, go to menu item menu item A3 Login or
C7.2.1 Login and set the device to the correct security level.
Program mode. If it is necessary to change this setting, go to menu item menu item A3 Login or
C7.2.1 Login and set the device to the correct security level.
How to change the password
• Push [>>>>] to enter Program Mode.
• Push 2 × [
• Push 2 × [
], [>>>>], 5 × [
], [>>>>], [
] and [>>>>] to go to the menu item C7.2.1 Login.
• Push [>>>>] to enter the menu item.
• Enter the password used at this time for a given security level ("Operator" or "Expert"). If it is
• Enter the password used at this time for a given security level ("Operator" or "Expert"). If it is
the default password, refer to the table at the start of this section.
• Push [^
^
^
^] and [
] to go to the menu item C7.2.2 Change Password.
• Push [>>>>] to enter the menu item.
• Enter the password used at this time for the security level set at the start of this procedure. If
• Enter the password used at this time for the security level set at the start of this procedure. If
it is the default password, refer to the table at the start of this section.
• Enter the new password.
i
If you change the password for the "Operator" security level, then the first three digits must
be zero (000x). The last digit can be a number (1...9) or a letter (A...F). If you change the
password for the "Expert" security level, then the first two digits must be zero (00xx). The
last two digits can be a number (1...9) or a letter (A...F).
be zero (000x). The last digit can be a number (1...9) or a letter (A...F). If you change the
password for the "Expert" security level, then the first two digits must be zero (00xx). The
last two digits can be a number (1...9) or a letter (A...F).
• Enter the new password again.
• Push 6 × [^
• Push 6 × [^
^
^
^] to go back to normal mode.
Operator
0009
•
Read: Measurement data and error messages available at
the "User" security level (normal mode and menu items B2
Actual Values and C7.3.1 Message View)
the "User" security level (normal mode and menu items B2
Actual Values and C7.3.1 Message View)
•
Change: Binary Output (C4.3)
•
Change: All HART® settings (C5) – but not C5.1.1 Current
Loop Mode
Loop Mode
NOTE:
NOTE:
NOTE:
NOTE: You can change the password for the "Operator"
security level in menu item C7.2.2 Change Password. Refer to
the INFORMATION! note that follows.
User
—
•
Read: Measurement data and error messages (normal mode
and men items B2 Actual Values and C7.3.1 Message View)
and men items B2 Actual Values and C7.3.1 Message View)
•
Read: All settings in menus A Quick Setup, B Test and C Full
Setup
Setup
•
Change: All settings in menu C6 Display (language, backlight
on/off, screen contrast and measurement data display
options (normal mode, pages 1 and 2)) and C7.5 Units
(length, volume, mass and custom units)
on/off, screen contrast and measurement data display
options (normal mode, pages 1 and 2)) and C7.5 Units
(length, volume, mass and custom units)
•
Change: Security level. Go to menu item A3 Login or C7.2.1
Login to change from "User" to "Operator" or "Expert"
security levels
Login to change from "User" to "Operator" or "Expert"
security levels
Figure 6-3: Lock symbol
1 Lock symbol. If the display shows this symbol, you cannot change the setting.