Norsat International Inc. NSLK3200 ユーザーズマニュアル

ページ / 108
Page 78
 
Norsat NewsLink
                                             
           099-20003-01OM 
                                                                    
Norsat
FIGURE 64.
Transmission Indicator.
2.
The transmitter turns OFF and reports the error 
C
OULD
 
NOT
 
TURN
 
ON
 
THE
TRANSMITTER
. This is likely due to over usage of the CPU.
i.
Close all running applications aside from the Norsat NewsLink GUI.
ii.
Turn the transmitter back ON.
3.
The transmitter is ON and a sudden loss of reception of the signal occurs,
however the Norsat NewsLink GUI still indicates the transmitter is ON.
This may be caused by an alarm on the modulator.
i.
Turn the transmitter OFF and then ON again.
ii.
Wait a few seconds for the signal to be received. If the signal is not
received, then a power down of the system is required.
4.
The transmitter is ON and suddenly turns OFF with no alarm indication on
the Norsat NewsLink GUI. This may be caused by a FIFO alarm on the
modulator.
i.
Ensure that the 70 MHz output of the modulator is properly connected
to the input of the upconverter with a 50 Ohm BNC cable.
ii.
Turn the transmitter back ON and wait a few seconds for the signal to
be received. If the signal is not received, then a power down of the
system is required.
Video Problems
1.
The transmitter is ON and there is a signal lock on the IRD, however there
is no video or the video is a pixelated screen. This is likely caused when
there is no video input signal going into the encoder.
i.
Check the video input connections and the video source.