Norsat International Inc. NSLK3200 ユーザーズマニュアル

ページ / 108
Norsat NewsLink
                                             
           099-20003-01OM 
                                                                    
Page 81
Appendix A
NewsLink GUI Status Indicators
The following sections give the help files for each of the status indicators on
the 
T
RANSMITTER
 S
TATUS
 screen.
Video Lock
Indicates whether or not the encoder is locked onto the incoming signal.
Range: 
0 to 1
The status bar will indicate:
0 (R
ED
): if the encoder is not locked onto the incoming signal
1 (G
REEN
): if the encoder is locked onto the incoming signal
Troubleshooting
1.
If the value is zero (R
ED
), determine the video input that is setup in your
profile; i.e. 
C
OMPOSITE
 or 
SDI
. Next, ensure the video source is connected
to the corresponding jack on the front of the baseband chassis. 
2.
If the video source is connected to the proper jack, however signal lock is
still zero, ensure that the video source is powered ON. Also, ensure that
the signal type coming out of your video source, i.e. 
NTSC
 or 
PAL
,
matches the signal type that is currently setup in your profile. 
3.
If you are using a low grade VCR or a very long cable, it may be possible
that the encoder will not be able to obtain a lock on the signal. 
Encoder Activity
Indicates whether or not the video encoder is active
Range: 