Omron Healthcare HEM6321T ユーザーズマニュアル

ページ / 2
SAFETY INFORMATION
INTENDED USE
The device is a digital monitor intended for use in measuring blood pressure and 
pulse rate in adult patient population with wrist circumference ranging from 5 1/4 
inches to 8 1/2 inches (13.5 cm to 21.5 cm). The device detects the appearance of 
irregular heartbeats during measurement and gives a warning signal with readings.
To assure the correct use of the product, basic safety measures should always be 
followed including the warnings and cautions listed in this instruction manual.
GENERAL USAGE
Contact your physician for specific information about your blood pressure. 
Self-diagnosis and treatment using readings may be dangerous. Follow the 
instructions of your physician or licensed healthcare provider.
DO NOT adjust medication based on readings from this blood pressure monitor. 
Take medication as prescribed by your physician. Only a physician is qualified to 
diagnose and treat High Blood Pressure.
The monitor is not intended to be a diagnostic device.
Consult your physician before using the device for any of the following conditions: 
common arrhythmias such as atrial or ventricular premature beats or atrial fibrillation, 
arterial sclerosis, poor perfusion, diabetes, age, pregnancy, pre-eclampsia, renal diseases.
Note that PATIENT motion, trembling, shivering may affect the reading.
Do not use the device on the injured wrist or the wrist under medical treatment.
Do not apply the wrist cuff on the arm while being on an intravenous drip or blood 
transfusion.
Contains small parts that may cause a choking hazard if swallowed by infants.
Consult your physician before using the device on the wrist with an arterio-venous 
(A-V) shunt.
Do not use the device with other medical electrical (ME) equipment simultaneously.
Do not use the device in the area the high frequency (HF) surgical equipment, 
magnetic resonance imaging (MRI), or computerized tomography (CT) scanner 
exists, or in the oxygen rich environment.
BATTERY USAGE
Keep the batteries out of the reach of young children.
DATA TRANSMISSION
Do not use this product on aircraft or in hospitals. Please remove the battery from 
the unit. This product emits radio frequencies (RF) in the 2.4 GHz band, use of this 
product in locations where RF is restricted is not recommended.
The use of RF in this product is licensed for use by the FCC/IC, for further 
information on any potential restrictions refer to documentation on Bluetooth
®
 usage 
by the FCC/IC.
GENERAL USAGE
Consult your physician before using the device for any of the following conditions:
• If you have had a mastectomy.
• If you have a condition that may compromise circulation, you may get an 
inaccurate reading with this device.
• People with severe blood flow problems or blood disorders as cuff inflation can 
cause bruising.
Do not take measurements more than necessary. It may cause bruising due to blood 
flow interference.
Read all of the information in the instruction manual and any other literature in the 
box before operating the unit.
Do not use this device on infants or persons who cannot express their intentions.
Operate the device only as intended. Do not use the device for any other purpose.
Do not use a mobile phone or other devices that emit electromagnetic fields near 
the device except when in use for wireless communications. This may result in 
incorrect operation of the device.
Do not use the device in a moving vehicle (car, airplane).
Use only Omron authorized parts and accessories. Parts and accessories not 
approved for use with the device may damage the unit.
Although this device is waterproof (IP22), please be careful about the operating 
environment.
BATTERY USAGE
Use only 1.5V Alkaline batteries with this device. Do not use other types of 
batteries. This may damage the device.
Do not replace the batteries while the data is transferred. 
SAFETY SYMBOLS USED IN THIS INSTRUCTION MANUAL
WARNING
Indicates a potentially hazardous situation which, if not 
avoided, could result in death or serious injury.
CAUTION
Indicates a potentially hazardous situation which, if not 
avoided, may result in minor or moderate injury to the user or 
patient or damage to the equipment or other property.
BEFORE TAKING A MEASUREMENT
To ensure a reliable reading, follow these recommendations:
1. Avoid eating, drinking alcohol, smoking, exercising, and bathing for 30 minutes
before taking a measurement. Rest for at least 5 minutes before taking the
measurement.
2. Stress raises blood pressure. Avoid taking measurements during stressful times.
3. The cuff can be applied to your left or right wrist.
4. Measurements should be taken in a quiet place.
5. Position the unit at heart level throughout the measurement.
6. Remain still and do not talk during the measurement.
7. Keep a record of your blood pressure and pulse readings for your physician. A 
single measurement does not provide an accurate indication of your true blood
pressure. You need to take and record several readings over a period of time.
Try to measure your blood pressure at the same time each day for consistency.
INTRODUCTION
Thank you for purchasing the OMRON BP654 Wrist Blood Pressure Monitor.
Fill in for future reference.
DATE PURCHASED: __________________
SERIAL NUMBER: ____________________
• Staple your purchase receipt here
• Register your product on-line at
www.register-omron.com
SAVE THESE INSTRUCTIONS
INSTRUCTION MANUAL
Model 
BP654
3200764-8A
Wrist Blood
Pressure Monitor
UNIT DISPLAY
DISPLAY SYMBOLS
HEARTBEAT SYMBOL (     )
The Heartbeat symbol flashes on the display at every heartbeat during the 
measurement.
AVERAGE READING SYMBOL (     )
The Average Reading Symbol is displayed when you press and hold the     button for 
more than 2 seconds. The most recent average reading appears on the display screen.
IRREGULAR HEARTBEAT SYMBOL (      )
When the monitor detects an irregular rhythm two or more times during the 
measurement, the Irregular Heartbeat Symbol will appear on the display with the 
readings.
An irregular heartbeat rhythm is defined as a 
rhythm that varies by 25% less or 25% more 
than the average rhythm detected while the 
monitor is measuring the systolic and diastolic 
blood pressure.
If the irregular heartbeat symbol displays with 
your readings, we recommend you consult your 
physician. Follow the directions of your physician.
MOVEMENT ERROR SYMBOL (     )
The Movement Error Symbol (      ) is displayed if you move your body during the 
measurement. Please remove the wrist cuff, and wait 2-3 minutes. Reapply the 
wrist cuff and take another measurement.
Normal Heartbeat
Irregular Heartbeat
Short Long
Blood 
pressure
Pulse
Pulse
Blood 
pressure
2 “AAA” 
Alkaline Batteries
Storage
Case
Instruction 
Manual
KNOW YOUR UNIT
Main Unit:
Components:
Quick Start 
Guide
SETTING THE DATE AND TIME
WARNING
 If battery fluid should get in your eyes, immediately rinse with plenty of
clean water. Contact a physician immediately.
 Keep the batteries out of the reach of young children.
TAKING A MEASUREMENT
1. Sit comfortably on a chair with your feet flat on the floor.
Keep your back straight. Place your elbow on a table and and
elevate cuff wrist to heart level.
NOTES:  
 The distance from the top of your seat measuring 
to the top of the table you are sitting at, should be 
12 ± 2 inches (30 ± 5 cm). If the distance 
measured between the top of your seat and table 
do not fall within this parameter, please correct 
your seat or table height. If you are unable to 
make any seat or table adjustments, please turn off the position 
indicator and position your wrist at heart-level by yourself.
• The cuff must be approximately the same height as your heart. If
the cuff is too high above your heart, your blood pressure will read
artificially low. If the cuff is too low below your heart, your blood
pressure will be artificially high.
• Relax your wrist and hand. Do not bend your wrist back, clench 
your fist, or bend your wrist forward.
As the cuff inflates, the monitor automatically determines your ideal inflation 
level. This monitor detects your blood pressure and pulse rate during inflation.
The Heartbeat Symbol (     ) flashes at every heartbeat.
Remain still and do not move until the entire measurement process is 
completed.
After the monitor has detected your blood pressure and pulse rate, the cuff 
automatically deflates. Your blood pressure and pulse rate are displayed.
NOTE:
 To stop the inflation or measurement, push the START/STOP button. 
The monitor will stop inflating, start deflating, and will turn off.
3. Press the START/STOP button to turn the monitor off.
USING THE MEMORY FUNCTION
The monitor automatically stores up to 100 readings. 
It can also calculate an average reading based on the last 3 readings taken within 
10 minutes. 
TO VIEW THE READINGS STORED IN MEMORY
1. Press the       button.
The Memory number appears for a second 
before the pulse rate is displayed. The 
most recent reading set is numbered “1”.
NOTES:  
 If the positioning indicator is set to 
“on” before the measurement, the 
positioning indicator is displayed 
with the readings.
 When viewing the readings taken without setting 
the date and time, “-:--” is displayed instead of the 
date and time.
• If there are no readings stored in the memory, the 
screen to the right is displayed.
2. Press the       button repeatedly to view the readings stored in the memory.
TO VIEW THE AVERAGE READING
When the unit is off, press and hold the       button for 
more than 2 seconds.
NOTES:  
 If the previous measurement was taken 
without setting the date and time, the 
average reading is not calculated.
• If there are only 2 readings in the memory for that
period, the average will be based on these 2 
readings.
• If there is 1 reading in the memory for that period, this is displayed as
the average.
1. Push down the hook of the battery cover and 
pull downward.
2. Install 2 “AAA” size batteries so the + 
(positive) and - (negative) polarities match the
polarities of the battery compartment as 
indicated.
3. Replace the battery cover.
NOTE:
 Make sure that the battery cover is 
securely in position.
BATTERY INSTALLATION
APPLYING THE WRIST CUFF
Display
Battery 
compartment
Memory button
START/STOP button
Transfer button
(Date/Time setting button)
Wrist cuff
Blood pressure level 
indicator (bar)
Date/Time display
Systolic blood
pressure
Average reading symbol
Positioning symbol
Diastolic blood
pressure
Battery symbol
(low/depleted)
Pulse display /
Memory number
Deflation symbol
Transfer symbol
Memory full
symbol
OK symbol
Positioning indicator
Memory symbol
Movement error symbol
Irregular heartbeat symbol
INTRODUCTION
Thank you for purchasing the OMRON BP653 Wrist Blood Pressure Monitor.
The monitor is compact and easy-to-use at home, at work, and during travel. Perfect 
for people who frequently monitor their own blood pressure.
Your new digital blood pressure monitor uses the oscillometric method of blood 
pressure measurement. This means the monitor detects your blood’s movement 
through your brachial artery and converts the movements into a digital reading. An 
oscillometric monitor does not need a stethoscope so the monitor is simple to use.
Clinical research has proven a direct relationship between blood pressure in the wrist 
and blood pressure in the arm. Changes in wrist blood pressure reflect changes in arm 
blood pressure because the arteries in the wrist and the arm are close to each other. 
Frequently measuring the blood pressure in your wrist will provide your physician 
with an accurate indication of changes in your blood pressure.
The BP652 comes with the following components:
• Monitor • Storage Case • 2 “AAA” Alkaline Batteries
• Instruction Manual printed in English and Spanish • Quick Start Guide
Please read this instruction manual thoroughly before using the unit. Please keep for 
future reference. For specific information about your own blood pressure, CONSULT
YOUR DOCTOR.
Fill in for future reference.
DATE PURCHASED: __________________
SERIAL NUMBER: ____________________
• Staple your purchase receipt here
• Register your product on-line at
  www.register-omron.com
INSTRUCTION MANUAL
Model 
BP654
3200764-8A
Wrist Blood
Pressure Monitor
Wrist Blood Pressure Monitor
GETTING
STARTED
BP654
3200765-6A
1
EN 2ES 3FR
The monitor is compact and easy-to-use at home, at work, and portable for travel. 
Perfect for people who frequently monitor their own blood pressure.
Your new digital blood pressure monitor uses the oscillometric method of blood 
pressure measurement. This means the monitor detects your blood’s movement 
through your brachial artery and converts the movements into a digital reading. An 
oscillometric monitor does not need a stethoscope so the monitor is simple to use.
Clinical research has proven a direct relationship between blood pressure in the 
wrist and blood pressure in the arm. Changes in wrist blood pressure reflect changes 
in arm blood pressure because the arteries in the wrist and the arm are close to each 
other. Frequently measuring the blood pressure in your wrist will provide your 
physician with an accurate indication of changes in your blood pressure.
The BP654 comes with the following components:
• Monitor
• Storage Case 
• 2 “AAA” Alkaline Batteries
• Instruction Manual  
• Quick Start Guide
Please read this instruction manual thoroughly before using the unit. Please 
keep for future reference. For specific information about your own blood 
pressure, CONSULT YOUR DOCTOR.
BLOOD PRESSURE LEVEL INDICATOR (BAR)
Blood pressure level indicator (bar) will light up between 
the systolic blood pressure and the diastolic blood 
pressure. 
2013 ESH/ESC Guidelines for the management of arterial hypertension
Definitions of hypertension by office and home blood pressure levels
Systolic Blood Pressure
Office
Home
≥ 135 mmHg
Diastolic Blood Pressure
≥ 85 mmHg
≥ 140 mmHg
≥ 90 mmHg
NOTES:  
 When the depleted battery symbol (         ) appears on the display, turn 
the monitor off and remove all the batteries. Replace with 2 new 
batteries at the same time. 
 Turn the unit off before replacing the batteries. If the batteries are
removed while the unit is still on, the date and time will be reset to 
that of the previous use. The readings are not deleted.
• When the batteries are replaced, you may need to reset the date and 
time. Refer to “Setting the Date and Time”.
• The batteries included with the device may have a shorter life.
1) Press the 
 button to change.
2) Press the 
 / 
button to confirm.
• Next setting appears.
1. When the unit is off, press the       /       button repeatedly until the year flashes 
on the display. 
Set the monitor to the correct date and time before taking a measurement for the 
first time.
2. Set the monitor to the correct date and time .
3. Press the START/STOP button to store the setting.
NOTES:  
 If the batteries have been removed, the date and time setting will 
need to be reset.
• The date and time can be automatically set when you transfer your
readings to the Omron Wellness App. However, the date/time will 
only be set for future measurements taken after the reading that was
transferred, it will not be saved to the reading that was just 
transferred.
• If the date and time are not set, “-:--” appears during or after
measurement.
NOTES:  
 The monitor will automatically turn off after 2 minutes.
• Wait 2-3 minutes between measurements. The wait time  allows the 
arteries to return to the condition prior to taking the blood pressure
measurement. You may need to increase the wait time depending 
on your individual physiological characteristics.
• Hold down to advance the digit
rapidly. 
Year
Month
Day
Hour
Minute
APPLYING THE CUFF ON THE LEFT WRIST
1. Roll up sleeve. Make sure your sleeve is not rolled up 
too tightly on your arm. This may constrict the flow of
blood in your arm.
2. Put your arm through the cuff loop. Your palm
should face upward.
3. Position the cuff leaving a clearance of approximately
1/2 inch (1 cm to 2 cm) between the cuff and the bottom
of your palm.
4. Wrap the wrist cuff firmly around your wrist.
Do not apply over clothing.
NOTES:
 • Make sure the wrist cuff does not cover the 
protruding part of the wrist bone on the 
outside of the wrist.
 If the wrist cuff comes off, re-assemble as
shown in the figure.
INFLATE
START
DEFLATE
COMPLETE
Alternating 
date/time 
display
Heartbeat symbol 
(Flashes during 
measurement)
TO DELETE ALL READINGS AND SETTINGS
You can delete all readings and settings when you want to dispose of the device or 
present it to others.
1. While holding the      /       button down, press the 
START/STOP button for more than 5 seconds.
2. When the CLr symbol appears, release the
     /       button and START/STOP button.
3. Press the START/STOP button to turn the
monitor off.
NOTES:  
 Unpairing your device will not delete the information in the mobile App.
• The monitor will automatically turn off after 2 minutes.
• If you re-pair your smartphone to your blood pressure monitor, all
prior reading history stored on the mobile App will be retained.
(Proper position)
(Wrist is too high)
(Wrist is too low)
(Forward-bent posture)
TO PAIR THIS DEVICE WITH A SMARTPHONE
To begin using the OMRON Wellness software for the first time, please visit 
www.omronwellness.com for the initial set-up instructions.
1. Download and install onto your smartphone, the free “Omron Wellness” App.
2. Open the App on your smartphone and follow set-up and pairing instructions.
NOTE:
 Please make sure that you do not currently have an
active reading screen on. If there is a reading on the 
screen,  press the START/STOP button to clear the 
screen to allow you to begin to transfer your readings.
3. Press and hold the       /      button for more than 2 seconds.
The transfer symbol (     ) will appear on the display.
4. Open the App on your smartphone and follow the device
pairing instructions shown on your smartphone, while the 
transfer symbol is flashing on the display.
5. The OK symbol and      will flash when pairing is completed.
Any readings currently saved in the blood pressure monitor's 
memory will automatically be transferred to the App after 
successful completion of the pairing process.
NOTES:  
 If the pairing has failed, the screen to the right is 
displayed.
• The monitor will automatically turn off after 10
seconds without any operations.
TO TRANSFER THE DATA
1. Open the App on your smartphone and log in.
2. Tap “Transfer Readings” on the App and follow the instructions.
NOTE:
 When the Memory full symbol (     ) blinks or is lit on the display, 
transfer the data before the readings are deleted.
Blinking:
 80 readings have been stored.
Lit:
 100 readings have been stored.
If the memory is full, the monitor will delete the oldest reading. Please 
transfer your readings to the Omron Wellness App to help ensure your 
data is saved before old readings are deleted from the memory.
TO DELETE ALL THE READINGS STORED IN MEMORY
1. Press the       button,  the memory symbol (      ) appears.
2. While holding the       button down, press the 
START/STOP button for more than 2 seconds.
NOTE:
 You cannot partially delete the 
readings stored in the memory. 
All readings will be deleted.
APPLYING THE CUFF ON THE RIGHT WRIST
When taking a measurement using the right wrist position 
the cuff as shown in the illustration.
1
EN 2ES 3FR
2. Press the START/STOP button to start the measurement.
All symbols appear on the display before starting the measurement.
Positioning Indicator - The monitor has a built-in positioning indicator that is used 
as an aid in determining if the monitor is at the correct height. It has been designed 
to work with most people so that when your wrist is at the correct position relative 
to your heart, the positioning indicator will be blue. If the positioning indicator 
changes to orange, the device may not be at the correct height relative to your 
heart. Due to difference in individual size and physique, this feature may not 
helpful in all cases and you may wish to turn off this feature. If you feel the 
position of the wrist according to positioning indicator's guidance does NOT match 
your heart level, please turn off this feature and follow your judgement. It can be 
disabled, see “Turn OFF (ON) the Positioning Indicator”.
NOTE:
 Even if the device is not positioned properly and the positioning indicator 
is orange, after 5 seconds the monitor will start the measurement and the 
wrist cuff will start to inflate.
GENERAL PRECAUTIONS
Do not subject the monitor to strong shocks, such as dropping the unit on the floor.
Do not submerge the device or any of the components in water.
Store the device and the components in a clean, safe location.
Changes or modification not approved by the manufacturer will void the user 
warranty. Do not disassemble or attempt to repair the unit or components. This 
may cause an inaccurate reading as well.
Do not use the device outside the specified environment. It may cause an 
inaccurate reading.
Dispose of the device, components and optional accessories according to applicable 
local regulations. Unlawful disposal may cause environmental pollution.
TURN  OFF (ON) THE POSITIONING INDICATOR
The positioning indicator is set “on” as default.
1. When the unit is off, press and hold the       /      and       button for more than 5
seconds to set the positioning indicator.
2. Press the START/STOP button to store the positioning indicator setting.
blue 
light
orange 
light
orange 
light
1
EN 2ES 3FR