26
Aruba 52
Part 0500007B
Installation Guide
August 2003
Connect power.
The Aruba 52 can receive electrical power using the following options:
z
POE–If connecting the Aruba 52 to a device that supplies IEEE 802.3af compliant POE
(see
(see
), no additional power connection is necessary.
z
Power Outlet
N
OTE
—
When the Aruba 52 is installed in an air-handling space, as described in NEC
(2002) Article 300.22(C), POE must be used instead of a power outlet.
If local regulations and practices permit, connect the included AC power adapter cable to
the DC power socket on the rear panel of the Aruba 52 and plug it into an appropriate
power outlet.
the DC power socket on the rear panel of the Aruba 52 and plug it into an appropriate
power outlet.
Reviewers:
Is shared secret config implemented?
C
AUTION
—
Be sure to comply with electrical grounding standards during all
phases of installation and operation of the AP. Do not allow the Aruba 52 or power
adapter (if used) to be connected to or make contact with metal or power outlets on a
different electrical ground than the device to which it is connected. Also, never con-
nect the AP to external storm grounding sources.
adapter (if used) to be connected to or make contact with metal or power outlets on a
different electrical ground than the device to which it is connected. Also, never con-
nect the AP to external storm grounding sources.
C
AUTION
—
Use only the AC power adapter supplied with this device. Other-
wise, the product may be damaged.
2