Connect power.
The Aruba 52 can receive electrical power using the following options:
z
POE–If connecting the Aruba 52 to a device that supplies IEEE 802.3af compliant POE 
(see 
 on 
), no additional power connection is necessary.
z
Power Outlet
N
OTE
When the Aruba 52 is installed in an air-handling space, as described in NEC 
(2002) Article 300.22(C), POE must be used instead of a power outlet.
If local regulations and practices permit, connect the included AC power adapter cable to 
the DC power socket on the rear panel of the Aruba 52 and plug it into an appropriate 
power outlet.
Reviewers:
Is shared secret config implemented?
C
AUTION
Be sure to comply with electrical grounding standards during all 
phases of installation and operation of the AP. Do not allow the Aruba 52 or power 
adapter (if used) to be connected to or make contact with metal or power outlets on a 
different electrical ground than the device to which it is connected. Also, never con-
nect the AP to external storm grounding sources.
C
AUTION
Use only the AC power adapter supplied with this device. Other-
wise, the product may be damaged.