INTRODUCTION
Congratulations on your purchase of the Hammacher Schlemmer 
Projection Alarm Clock and Weather Monitor. The basic package comes 
with a main unit (the weather forecast station), two remote wireless 
weather sensing units (operating at 433 MHz), and an AC adapter (AC 
120V, 60Hz-DC5.0V, 100mA).
PRECAUTIONS
This product is engineered to give you years of satisfactory service if 
handled carefully. Here are a few precautions:
1. Do not immerse the unit in water.
2. Do not clean the unit with abrasive or corrosive materials. They may 
scratch the plastic parts and corrode the electronic circuits.
3. Do not subject the unit to excessive force, shock, dust, temperature, or 
humidity, which may result in malfunctions, shorter lifespan, damaged 
batteries, and damaged parts.
4. Do not tamper with the unit's internal components. Doing so will 
invalidate the warranty and may cause damage. The unit contains no 
user-serviceable parts.
5. Only use fresh batteries. Do not mix new and old batteries.
6. Read the user's manual thoroughly before operating the unit.
A. LCD DISPLAY
For easy reading of indoor and outdoor weather conditions, calendar, and 
clock.
B. CHANNEL BUTTON
Toggles between the three remote sensor readings. 
C. ALARM BUTTON
For setting alarm and displaying alarm status.
D. MODE BUTTON
Toggles between display modes and allows manual setting of clock and 
calendar.
E. LIGHT/SNOOZE BUTTON
Activates the snooze function and backlighting.
F. DOWN (-) BUTTON
Decreases the value of a setting.
G. UP (+) BUTTON
Advances the value of a setting.
H. BATTERY COMPARTMENT
For two “AA” batteries.
I. PROJECTION LIGHT AND ADJUSTMENT
* Press E / I [LIGHT/SNOOZE]- Projection light will come on and turn 
off automatically after 5 seconds.
* Turn the dial J [ROTATE] to manually rotate the projection display.
* Press button K [FLIP] to rotate the projection display 180°.
* Turn the focus dial L [FOCUS] to adjust the sharpness of projection 
display.
* When AC adapter is plugged in, slide button M [CONTINUE - 
PROJECTION] for continuous time and temperature projection.
N. LIGHT SENSOR BUTTON
When the AC adapter is plugged in, position the light sensor switch at:
* “AUTO” for automatic LCD backlighting when the room grows dark.
* “ON” for continuous LCD backlighting.
* “OFF” to deactivate LCD backlighting.
NOTE: AC Adapter must be plugged in for the light sensor option to work            
O. LIGHT SENSOR
P.OUTDOOR TEMPERATURE
Remote unit temperature
Q. INDOOR TEMPERATURE
Main unit temperature
MAIN FEATURES: REMOTE UNIT(S)
A. LED INDICATOR
Flashes once when the remote unit transmits a reading to the main unit.
Flashes twice to indicate low battery.
B. BATTERY COMPARTMENT
For two “AA” batteries.
C. RESET BUTTON
Resets unit in case of channel selection change.
D. CHANNEL SELECTOR
To coordinate the sensor with the main unit, select the desired channel 
number before installing batteries.
E. WALL-MOUNT RECESSED HOLE
MANUAL SETTINGS
It is necessary to set the desired US TIME ZONE.
1. Press MODE button so that the Day of the Week abbreviation is 
displayed to the right of the time; for example 2:37 TU.
2. Select the Time Zone by pressing and holding “+” button for 3 seconds.
3. Keeping holding “+” button until the desired US Time Zone (Pacific, 
Mountain, Central, Pacific) is highlighted on the display’s US map, 
located to the right of the time display above the day of the week.
4. Release the “+” button, the Time Zone is set.
HOW TO SET THE CLOCK MANUALLY
Press and hold MODE for 3 seconds: the display will flash the year. Press 
“+” or “-” to change the values of the flashing digits.
After the first value is set, press MODE again. Continue setting month, 
day, hour, minutes, language, and Fahrenheit or Celsius display option. 
When you’ve set the last value, press MODE a final time to return to 
regular mode. Display will stop flashing.
The clock can also be set atomically. See section How to Set the Radio 
Controlled Clock.
P
Q
The Hammacher Schlemmer 
Projection Alarm Clock and 
Weather Monitor.
BEFORE YOU BEGIN
For best operation,
1. Insert batteries into remote sensors before inserting batteries in the 
main unit.
2. Position the remote units and main unit within effective transmission 
range, typically up to 100 feet. Note that the effective range depends 
upon many factors, including structural surroundings. Though the 
remote units are weatherproof, they should be placed away from direct 
sunlight, rain, and snow.
BATTERY INSTALLATION: REMOTE UNITS
1. Remove the screws on the battery compartment.
2. Select the desired channel.
3. Install 2 alkaline “AA” batteries.
4. Replace battery compartment door and secure screws. 
BATTERY INSTALLATION: MAIN UNIT
1. Open the battery compartment door.
2. Install 2  alkaline “AA”.
3. Replace the battery compartment door.
LOW BATTERY WARNING
A low-battery indicator [       ] will appear on the indoor or outdoor 
temperature reading to show when the corresponding sensor’s batteries 
need replaced.
GETTING STARTED
After batteries are installed, remote sensors will transmit temperature 
readings at 45 second intervals. The main unit may take up to two minutes 
to receive the initial readings; upon successful reception, outdoor 
temperatures will be displayed. The main unit will automatically update 
readings at about 45-second intervals.
If no signals are received by the main unit after two minutes, “-- ” will be 
displayed. Hold [-] for 2 seconds to begin another signal search.
If no signals are received, try moving the base unit closer to the remote 
sensor, face the remote sensor towards the base unit, and minimize 
obstructions such as doors and walls between the sensor and base unit. 
2