Murata Machinery Limited Logistics & Automation Division DVM192 ユーザーズマニュアル

ページ / 35
[USER NAME]
Approval Specifications for [TYPE NAME]  (SRCC-Electrical)                            (34 / 35)
                                             
©Murata Machinery,LTD.Clean Systems Division/ Engineering Dept.
DOC.No.
[DOCUMENT NUMBER]
(4) Perform the procedure to register SRC.
Select the vehicle registration operation on the operation screen of OPC.
=>
The vehicles whose registrations are completed are scrolled and
displayed.
Select the interruption after completing the registration of all the
vehicles in the system.
Return to the Main Monitor screen and select the Automatic operation
mode.
=>
The system status switches from “Manual” to “Automatic” mode.
(5) Connect SRCC with the Host in the on-line status.
(SRCC is automatically connected to the Host when it starts up.)
(6) The Host sends transport commands to SRCC.
=>
SRC starts transport operations.
Operation stop
(1) Stop SRC temporarily.
Select the temporary stop mode on the Main Monitor screen.
=>
SRC makes a cycle stop after completing all transport commands that
it holds.
(2) Stop the local equipment.
(For more information, see the operation procedures for the local equipment.)
- MPC  operation  panel
Press the high-frequency power OFF switch.
=>
The high-frequency power supply indicator goes out.
=>
The power of the vehicle is shut down and the indicator goes out.
- High-frequency power supply
Turn the main breaker off.
=>
The power supply indicator goes out.
- Shunting device
Turn the main breaker off.
(3) Turn the main breaker off.