Laerdal Medical AS 150-00001 ユーザーズマニュアル

ページ / 36
 
2004-10-08  
5
Items included 
Please check that all listed contents below are included.   
−  Torso including: 
ƒ  Airway Management Head  
ƒ  Pelvis  
ƒ  Blood Pressure arm with cuff 
ƒ  IV arm 
−  Extrication / Rescue Legs 
−  Remote Control including batteries 
−  Remote Control cable (for use when RF communication is not allowed) 
−  Power cord for AC wall adapter  
−  1 bottle simulated blood 
−  1 can Lubricant 
−  Manual defibrillation plates  
−  Full body soft pack  
−  Resusci Anne Simulator Eye Set 
−  Air pump 
−  Directions for Use  
−  Track suit including jacket and pants 
−  Educational Support Manual with predefined training scenarios 
−  Software CD and USB interface cable 
Unpack 
The Resusci Anne Simulator is packaged without the legs attached. Remove the upper 
body and legs from the packaging and attach the legs to the torso. 
Attaching the Legs 
Each leg is attached to the pelvis with a bolt, two washers, a spring and a wing nut.   
 
To attach Legs: 
1.  Detach the torso’s lower chest skin and fold back as shown in picture below. 
2.  Remove the stomach pillow insert. 
3.  Remove the pelvis from the torso via bolt connection as shown in picture below. 
 
Note: Be careful when detaching the pelvis from the torso for assembly of 
the legs as there are connection wires from the pelvis to the torso.     
  
 
 
 
 
4.  Remove wing nut and washer from bolt inserted in the leg. (Leave spring assembly 
in thigh of leg.) 
5.  Insert bolt through hole in pelvis 
6.  Slide washer and wing nut back over bolt. 
7.  Use a screwdriver to drive bolt into wing nut  
8.  Reattach the pelvis, with legs attached, to the torso via bolt connector  
 
 
 
To remove legs, reverse procedure.