Intel R1304BTSSFAN ユーザーズマニュアル

ページ / 67
Intel
®
 Server System R1304BTSSFAN/R1304BTLSFAN/R1304BTLSHBN TPS
                                                                                  
Appendix B: Integrated BMC Sensor Tables 
Revision 2.0 
 
 
 
 
43 
Intel order number G17455-004 
Full Sensor Name 
(Sensor name in SDR) 
Sensor 
# 
Platform 
Applicability 
Sensor Type
Event/Reading 
Type 
Event Offset Triggers
Contrib. To 
System Status 
Assert/De-
assert 
Readable
 
Value/Off
sets 
Event
Data 
Rearm
Stand-by 
System Event 
(System Event) 
08h All 
System 
Event 
12h 
 
Sensor Specific 
6Fh 
 
04 – PEF action 
 
OK As 
Trig 
Offset 
A X 
Button Sensor 
(Button) 
09h All 
Button/Switc

14h 
Sensor Specific 
6Fh 
00 – Power Button 
02 – Reset Button 
OK AS 
Trig 
Offset 
A X 
PCH Thermal Trip 
(PCH Therm Trip) 
0Dh All 
Temperature 
01h 
Digital Discrete 
03h 
01 – State Asserted 
Fatal 
As and 
De 
– 
Trig 
Offset 
M X 
Baseboard 
Temperature 1 
(Baseboard Temp) 
20h All 
Temperature 
01h 
Threshold 
01h 
[u,l] [c,nc] 
nc = Degraded 
c = Non-fatal 
As and 
De 
Analog R, 
Front Panel 
Temperature 
(Front Panel Temp) 
21h All 
Temperature 
01h 
Threshold 
01h 
[u,l] [c,nc] 
nc = Degraded 
c = Non-fatal 
As and 
De 
Analog R, 
PCH 
TemperatureNote1 
(PCH Temp) 
22h All 
Temperature 
01h 
Threshold 
01h 
[u,l] [c,nc] 
nc = Degraded 
c = Non-fatal 
As and 
De 
Analog R, 
Baseboard 
Temperature 3 
(Inlet Temp) 
24h All 
Temperature 
01h 
Threshold 
01h 
[u,l] [c,nc] 
nc = Degraded 
c = Non-fatal 
As and 
De 
Analog R, 
Hot-swap Backplane 
Temperature 
(HSBP Temp) 
29h All 
Temperature 
01h 
Threshold 
01h 
[u,l] [c,nc] 
nc = Degraded 
c = Non-fatal 
As and 
De 
Analog R,