Sensors & Software Inc. NG250 ユーザーズマニュアル

ページ / 155
11-Locate & Mark Mode
Noggin
60
11.4 Image Settings Screen
The Image Settings Screen is accessed by pressing the Pause (||) button while in the Scanning
Screen or the Locating Screen.  Menu options appear along the bottom of the screen:
11.4.1 Scan
To exit from the Image Settings Screen and resume Scanning, press the Scan button or the
Pause (||) button again (to unPause).  The Scanning Screen returns at the current location with
the position information preserved.  
If, while paused in the Image Settings Screen, the cart has moved more than a few centimeters,
when scanning is restarted, a gap called a Position Break will appear in the image.  The position
break is also indicated by a message on the bottom of the screen and the Position Axis along the
top of the data image resetting to zero.