Zagg ZKLI ユーザーズマニュアル
3855 South 500 West Ste Q | Salt Lake City, Ut | 84115 | 801.506.7081
21
channel selection key has not changed. Maximum timeout period TBD. In an
Idle state Limitless Keyboard will remain in connection with Host.
Idle state Limitless Keyboard will remain in connection with Host.
3.18 EMI
Test
European Standard EN 55022: 2006 Class B.
FCC/CFR 47 : Part 15 Class B
Frequency Range of Test: from 30MHz to 1000 MHz
3.19 ESD
TEST
Basic standard: IEC 61000-4-2
Generic standard: EN 55024:1998 + A1:2001 + A2:2003
Performance Criteria: B
Level: 2 for Contact discharge
Tested Voltage: ± 8V for Air discharge, ± 4 KV for Contact discharge
Temperature: 15-23 ºC
Relative Humidity: 30-60 % RH
Test Condition : Air ±8Kv, ±15Kv ESD
Judgment Standard:
±8Kv No malfunction
±15Kv No deviation or destruction of component
3.20 EFT
Test
Basic standard: IEC 61000-4-4
Generic standard: EN 50 082-1
Performance Criteria: B
Level: on Power Supply 3
Test Voltage: on Power Supply ± 1 KV
Temperature:15-35ºC
Relative Humidity: 30-60 % RH