4.10   Endurance Test 
Test  Item
 
Specification
 
Test  Equipment
 
Endurance 
test/Static 
load test
 
 
Cradle: There shall be no damage, when a 
load of 25N is applied in pressure direction 
for 15 seconds. 
 
 
Cradle: There shall be no damage, when a 
load of 25N is applied & released in pressure 
direction for 10,000 cycles. 
 
 
KB bezel and Bottom cover endurance: 
There shall be no damage, when a load of 
25N is applied in pressure direction for 15 
seconds. 
 
 
Rubber pad endurance: Rubber pad does not 
peel off when a load of 10N is applied on its 
surface.
 
Pull gauge. 
 
 
4.11   Physical / Software compatibility check 
Test  Item
 
Specification
 
Test  Equipment
 
Physical / 
Software 
compatibility 
check
 
Physical / Software Compatibility Test
 
 
 
 
4.12   PLP – Product Liability  Program 
Test  Item
 
Specification
 
Test  Equipment
 
PLP
 
1.   Electronic, Physical PL review, 
Manual/Package safe clause review
 
 
 
 
 
4.13  Abrasion Test – Legend (1X key silk-screen printing)
 
Test  Item
 
Specification
 
Test  Equipment
 
Abrasion test- 
legend
 
1,250 cycles, 450g , CS-10F eraser, 50% 
legend line width missing or damaged
 
Fixture