Zagg ZKSI ユーザーズマニュアル
Test Item
Specification
Test Equipment
High Temp
High Humidity
Test
High Humidity
Test
1. Sample size: 5 pieces
2. Test Condition: 50°C /95%, 120 hours
3. Judgment Standard:
2. Test Condition: 50°C /95%, 120 hours
3. Judgment Standard:
No malfunction
No decay inside of the product
Chamber
Storing in Low
Temperature
Temperature
1. Sample size: 5 pieces
2. Test Condition: -20°C, 96 hours
3. Judgment Standard:
2. Test Condition: -20°C, 96 hours
3. Judgment Standard:
- No malfunction
Chamber
4.3. Heat Treatment Impact Test
Test Item
Specification
Test Equipment
Heat Treatment
Impact Test
Impact Test
1. Sample size: 5 pieces
2. Test Condition: -40°C ~ 85°C, 2 hours /cycle,
2. Test Condition: -40°C ~ 85°C, 2 hours /cycle,
30cycle
3. Judgment Standard:
No malfunction
No decay or color change of PBA Soldering
& component
& component
No crack, dent, or change
Chamber
4.4. Vibration Test
Test Item
Specification
Test Equipment
Vibration
1. Sample size: 5 pieces
2. Condition: Sine sweep: 10HZ~ 500HZ~ 10HZ;
3. Sweep speed: 0.5 Octave/minute
4. Acceleration: 2G
5. Duration: 30 minutes per face.
6. Judgment Standard:
2. Condition: Sine sweep: 10HZ~ 500HZ~ 10HZ;
3. Sweep speed: 0.5 Octave/minute
4. Acceleration: 2G
5. Duration: 30 minutes per face.
6. Judgment Standard:
i) The mechanical appearance and inner
structure should not be damaged after test.
ii) No functional failure should be found during
and after the test.
structure should not be damaged after test.
ii) No functional failure should be found during
and after the test.
Vibration machine