Zagg ZKSM ユーザーズマニュアル

ページ / 34
 
 
Heat Treatment 
Impact Test 
1.  Sample size: 5 pieces 
2.  Test Condition: -40°C ~ 85°C, 2 hours /cycle, 
30cycle 
3.  Judgment Standard: 
•  No malfunction 
•  No decay or color change of PBA Soldering 
& component 
•  No crack, dent, or change 
Chamber 
 
4.4.  Vibration Test 
 
Test  Item 
Specification 
Test  Equipment 
Vibration 
1.  Sample size: 5 pieces 
2.  Condition: Sine sweep: 10HZ~ 500HZ~ 10HZ; 
3.  Sweep speed: 0.5 Octave/minute 
4.  Acceleration: 2G 
5.  Duration: 30 minutes per face. 
6.  Judgment Standard: 
i) The mechanical appearance and inner 
structure should not be damaged after test. 
ii) No functional failure should be found during 
and after the test. 
Vibration machine