Zagg ZKSM ユーザーズマニュアル

ページ / 34
 
 
Spillage test 
Unit shall be ON. 
The keyboard shall be functional after performing the 
liquid spill tests: 
 
Pour the liquid from a funneled system from a height 
of 3.0" above the keyboard over between the G, B, and 
H keys. The funnel should accurately dispense all the 
liquid at a rate of approximately 4 Oz (116 cc) per 
minute of elapsed time. The Keyboard shall remain idle 
for 60 seconds and then the keyboard shall be tilted to 
drain the liquid. Liquid for test: 
(1)  8.0 fluid oz. of hot coffee mixture (65C±5C) 
(Coffee mixture shall be prepared by adding 4.0 
gm. of sugar and 2.0 gm. of non-dairy creamer 
to an 8.0 oz. cup of hot coffee.). 
(2)  1.0 fluid oz. of cold sugared Cola (15C ±5C) 
(3)  350cc of water (24±2°C):Don’t shake keyboard 
after complete spilling water, Pour out water. 
Pass Criteria 
•  All keys on the keyboard are functional 
•  Liquid effectively drains from the specific 
keyboard liquid drain hole(s) Fail Criteria 
•  Liquid does not pass through keyboard and 
into the drain hole(s) and out the bottom of 
the keyboard 
•  Spontaneous characters appearing on the 
screen. 
•  Repeating keys (a repeating key is a key cap 
that is depressed and release once but 
continues to scroll the character more than 
once) 
Non-Functioning keys 
 
 
4.10. 
   Endurance Test 
Test  Item 
Specification 
Test  Equipment