3.2  3e-523E-900 Hardware Installation   
This  section  deals  with  installation  of  the  3e-523E-900  unit.  The  unit  requires  physical  mounting  and 
installation on the site, following a specific placement design ensuring optimum operation. 
FCC  Regulations  require  that  the  3e-523E-900  product be  professionally  installed  by  an  installer 
certified  by  the  National  Association  of  Radio  and  Telecommunications  Engineers  or  equivalent 
institution. 
The package includes the following items: 
 
The Device. 
 
Documentation as PDF files (housed on a CD-ROM). 
 
Registration and Warranty cards. 
Minimum System and Component Requirements   
To complete the configuration, you must have    the following minimal components:   
 
PCs  with  one  of  the  following  operating  systems  installed: Windows  NT  4.0,  Windows  2000  or 
Windows XP. 
 
Access to at least one laptop or PC with an Ethernet card, and cable that can be used to complete 
the initial configuration of the unit.   
 
A Web browser program (such as Microsoft Internet Explorer 6.0 or later, or Netscape 6.3 or later) 
installed on the PC or laptop you will be using to configure the Access Point.   
3.2.1  Specifications   
ELECTRICAL SPECIFICATIONS: 
Operating Voltage: 
110/220VAC, 50/60Hz 
Power Requirements: 
5.5 Watts (> 0°C) 
15 Watts (< 0°C, internal heaters operating) 
External Interfaces: 
Ethernet, 10/100, standard RJ-45 interface 
N-type female jack antenna connector 
Radio Transmission : 
902-928 MHz band
 
 
ENVIRONMENTAL SPECIFICATIONS: 
Operating 
Temperature: 
-30 to +50°C External Ambient (-22 to +122 °F) 
Storage Temperature: 
-40 to +70°C (-40 to +158 °F) 
Relative Humidity: 
90%, non-condensing