Alvarion Technologies Ltd. BMAX-BA36 ユーザーズマニュアル

ページ / 334
 
196
Operation
Chapter 4 - Operation and Administration
4.10.7.3.11.3Discrete Frequencies
The Discrete Frequencies menu enables viewing and editing the list of discrete 
frequencies that will be included in the Frequency Scanning Table. The Discrete 
Frequencies menu includes the following options:
„
Show: Select this option to view the current list of discrete frequencies (if any)
„
Update List: Enter a list of up to 10 discrete frequencies, separated by 
commas (no space). This list will replace the current list of discrete 
frequencies.
„
Add Frequency: Enter one frequency to be added to the current list of discrete 
frequencies.
„
Delete Frequency: Enter one frequency to be removed from the current list of 
discrete frequencies.
„
Delete All: Select this option to delete the entire list of discrete frequencies.
4.10.7.3.11.4Update Scanning Table
Select this option to update the frequency scanning table in run time (without 
resetting the unit).
4.10.7.3.11.5Force Full Scanning
Select this option to initiate a full scanning process.
4.10.7.4
Performance Monitoring
The Performance Monitoring sub-menu provides the following options:
„
Ports Counters
„
Burst Error Rate Counters
4.10.7.4.1
SU Ports Counters
The SU Ports Counters menu enables viewing or resetting the Ethernet and 
Wireless ports counters. The information displayed for each counter is the 
accumulated number since the last time the counters were reset. The counters 
are reset each time the SU is reset, or upon activating the Reset Counters option.
The displayed counters include:
„
Ethernet Port Counters