Alvarion Technologies Ltd. BMAX-BA36 ユーザーズマニュアル

ページ / 334
NPU Parameters Summary
BreezeMAX Modular Base Station System Manual
243
4.12
NPU Parameters Summary
Table 4-23: NPU Monitor Parameters Summary
Parameter
Range
Default
Run-Time 
Updated
Base Station Configuration Parameters
Device Name
Up to 255 printable characters
Null
Yes
Device Location
Up to 255 printable characters
Null
Yes
Switching Mode
1 - Ethernet CS 
2 - IP CS 
Ethernet CS
No
ATPC Enable/Disable
1 - Disable 
2 - Enable  
Disable is temporary until next reset of the 
NPU or AUs
Enable
Yes
Optimal Uplink RSSI (dBm)
-90 to -60 (-80 to -74 at the AUs)
-73 
(-74 at the AUs)
Yes
Operator ID
X.X.X
X: 0-255
186.190.0
No
Cell ID
X.X
X: 0-255
0.250
No
Duplex Mode
FDD, TDD
Only TDD spplicable to current version)
TDD
No
DL-UL Ratio
1: 65-35 (%)
2: 60-40 (%)
3: 55-45 (%)
4: 50-50 (%)
5: 45-55 (%)
6: 40-60 (%)
7: 35-65 (%)
 for limitations)
50-50 (%)
No
External 1PPS Clock
1 - Disable 
2 - Enable
Enable
No