Alvarion Technologies Ltd. BMAX-BA36 ユーザーズマニュアル

ページ / 334
38
Installation
Chapter 2 - Installation Guidelines
2.1.6
Connecting the Cables
2.1.6.1
Connecting the Grounding Cable
The Grounding screw (marked
) is located on the bottom panel of the outdoor 
unit.
1
Connect one end of a grounding cable to the grounding screw and tighten the 
grounding screw firmly. 
2
Connect the other end of the grounding cable to a good ground (earth) 
connection.
CAUTION
Do not open the impermeability test screw - you may impair the sealing of the unit against moisture 
and humidity.
Table 2-3: AU-ODU LEDs
Name
Description
Functionality
PWR Power 
indication
„
Off - Power failure
„
Green - Power to ODU is OK, internal 3.3 
VDC power supply is OK.
ALARM
IDU-ODU communication and 
synthesizer status indication
„
Off - IDU-ODU communication is OK, 
synthesizer is locked.
„
Red - IDU-ODU communication failure or 
synthesizer is not locked
ETH
Not Used
Table 2-4: AU-ODU Connectors
Name
Connector
  Functionality
IF
TNC jack
Connection to the AU-IDU/ODU Power Feeder
ANT
N-Type jack, 50 Ohm
Connection to an external antenna
 (GND)
Grounding screw
Connection to ground (earth)
 To connect the grounding cable: