Alvarion Technologies Ltd. BMAX-BA36 ユーザーズマニュアル
46
Installation
Chapter 2 - Installation Guidelines
2.2.5.1
Preparing a Power Cable for the regular (35A) PIU
A 2.5m DC power cable is supplied with each chassis. Additional DC cables can
be ordered from Alvarion. If necessary, use the following instruction to prepare a
DC cable.
be ordered from Alvarion. If necessary, use the following instruction to prepare a
DC cable.
1
Use a cable capable of supporting a current of at least 40A. Use a cable with 2
x 8AWG (or thicker) wires for the power plus an additional 8AWG to 20AWG
ground wire.
x 8AWG (or thicker) wires for the power plus an additional 8AWG to 20AWG
ground wire.
2
The matching power connector to be used is Amphenol D-type power P/N
177TWA/3W3/SP3Y with high power socket contacts P/N 17DM53744-1.
177TWA/3W3/SP3Y with high power socket contacts P/N 17DM53744-1.
3
Connect the cable to the power connector as follows:
Pin 1 (RTN): Red (8 AWG min wire)
Pin 2 (-48V): Black (8 AWG min wire)
Pin 3 (
): Ground (shield) (8AWG-20AWG wire)
Table 2-6: PIU LEDs
PWR and
MASTER/ACT LEDs
MASTER/ACT LEDs
PIU Status
PWR
MASTER/
ACT
Off
Off
Chassis is not connected to power
Red
Off
Power input is out of range or PIU card is damaged. Chassis is powered by the
redundant PIU
Red
Green
Power input is out of range or PIU card is damaged. Chassis is powered by the PIU
Green
Off
Power to PIU is OK. PIU is in redundant mode and the chassis is powered from the
other PIU
Green
Green
Power to PIU is OK. The chassis is powered from the PIU.
HOT SWAP LED
Off: Power from the module to the chassis is not disconnected, the PIU is not ready for
removal
Blue: Power from the module to the chassis can be disconnected and the PIU can be
safely removed
For instructions on using the HOT SWAP handles refer to
To prepare the power cable: