20 
© 1998-2006 RF IDeas, Inc. 
 
Force data to length 
This applies to both Facility and ID code data fields. 
Zeroes are added to the front of the data to create a 
specific length.  For example, if the data were 567 and 
the length is set to 6, the output will be 000567. 
 
FAC fixed to this length 
Zeroes are added to the front of the FAC portion of the 
data to create a specific length.   
 
Send ID Code 
Since there are two fields of data (ID and FAC) and 
sending at least one is necessary, this field really implies 
send the ID and not the FAC data.  If both fields need to 
be sent, you need to select the ‘Send the FAC code’ 
checkbox. 
 
Bit count of ID portion only 
This field is used to define the bit count of ID portion of 
the card data.  To retrieve this data properly, you will 
need to also indicate and strip the Leading and Trailing 
parity bits. 
 
ID fixed to this length 
Zeroes are added to the front of the ID portion of the 
data to create a specific length.   
 
Enable FAC/ID character 
This checkbox indicates that a separator character will 
be used between the FAC and ID codes.  
 
This char sent between FAC & ID 
This field holds the character that will be placed between 
the FAC and ID codes. Note there are 3 special 
characters (hex 01, 02, 03) that can be specified.  These 
add an extra measure of difficulty in reproducing card 
data directly from the keyboard.  It may be useful when 
using the proximity reader as a logon device.  Please 