Force data to length
This applies to both Facility and ID code data fields.
Zeroes are added to the front of the data to create a
specific length. For example, if the data were 567 and
the length is set to 6, the output will be 000567.
FAC fixed to this length
Zeroes are added to the front of the FAC portion of the
data to create a specific length.
Send ID Code
Since there are two fields of data (ID and FAC) and
sending at least one is necessary, this field really implies
send the ID and not the FAC data. If both fields need to
be sent, you need to select the ‘Send the FAC code’
checkbox.
Bit count of ID portion only
This field is used to define the bit count of ID portion of
the card data. To retrieve this data properly, you will
need to also indicate and strip the Leading and Trailing
parity bits.
ID fixed to this length
Zeroes are added to the front of the ID portion of the
data to create a specific length.
Enable FAC/ID character
This checkbox indicates that a separator character will
be used between the FAC and ID codes.
This char sent between FAC & ID
This field holds the character that will be placed between
the FAC and ID codes. Note there are 3 special
characters (hex 01, 02, 03) that can be specified. These
add an extra measure of difficulty in reproducing card
data directly from the keyboard. It may be useful when
using the proximity reader as a logon device. Please
see application note for more details.