3.  Device appears with yellow bang (!) on device manager 
This could happen when drivers are not found for this device or when drivers fail 
to load.  The drivers for this device are available on Windows Update or can be 
downloaded from 
http://www.scmmicro.com
.  If the failure is due to driver load 
failure, then the reason for driver load failure can be inferred from the device 
manager message at the General tab. 
 
4.  Contact less cards are not detected 
This could happen when module is placed in proximity to something made out of 
metal.  Ensure that there is not metal in proximity between the antenna and the 
card. 
 
5.  Contact card is not detected 
Check the connections on the two pin header.  The terminals should be continuous 
when a card is inserted. 
 
6.  Contact card cannot be read 
Ensure that the cables between (both five and four pin) headers and the smart card 
connector are of same length and type.  
 
 