TYPICAL STANDARD INSTALLATION
The illustration (A) shows typical standard UV installation.
WARNING
Before mounting the device to any wall or ground
surface, double check with your local government or
construction agents to avoid drilling to any hidden
electricity cables or gas pipes. The damage might be
dangerous.
MOUNTING THE STAND ON A WOOD SURFACE
(Before attaching to the aluminum pole)
Secure the stand to the mounting surface by driving the
screws into the appropriate holes. Please refer to the illustration (B).
MOUNTING THE STAND TO THE POLE
(Before attaching to the aluminum pole)
Secure the stand to the mounting object (Such as metal pole) by driving the
screws through the stand’s holes to the metal plates
and then attach with hex nuts. Please refer to the illustration (C).
MOUNTING TO THE SOIL
First attach the plastic tip to the aluminum pole by rotating clockwise and then
insert into the soil. Please refer to the illustration (D).
TROUBLE SHOOTING FOR LOSTING SIGNALS (If the receiving unit is
available)
If without obvious reasons the display for UV channel suddenly goes (---) dash check:
1. The wireless UV sensor is still in place
2. The batteries of both the receiving and the remote unit. Replace them as necessary.
3. The transmission is within range and the path is clear of obstacles and interferences. Shorten the
distance when necessary.
4. Signal from other household devices, such as bell, home security system and entry controls, which
may cause interference and temporary reception failure. This is normal and it doesn’t affect the
general performance of the product. The transmission and reception of UV reading will resume once
the interference recedes.
MAINTENANCE
1. In view of safe operation, alterations to this device are strictly prohibited.
2. Avoid touching the small transparent lens on the top of this UV sensor. Any oil on this surface will
degrade the sensitivity of the sensor. To remove any oil present, clean the lens with a clean swab
and ethyl (denatured) alcohol. Do not use rubbing alcohol.
3. Do not immerse the unit into water. If the unit comes in contact with water, dry it immediately with a
soft lint-free cloth.
4. Do not clean the unit with abrasive or corrosive materials. Abrasive cleaning may scratch the plastic
parts and corrode the electronic circuit.
5. Do not subject the unit to excessive force, shock, dust, temperature or humidity. Such treatment
may result in malfunction, a shorter electronic life span, damaged batteries, or distorted parts.
6. Do not tamper with the unit’s internal components. Doing so will terminate the unit’s warranty and
may cause damage. The unit contains no user-serviceable parts.
7. Do not leave used-up batteries in the units (even leak proof batteries) as these may corrode and
release chemicals, which may damage this product and also be dangerous to health.
8. Inserting batteries in an incorrect polarity will cause damage to this product. Do not mix new and old
batteries, as old ones may leak.
9. Do not dispose of new or used batteries to fire due to dangers of explosion or release of dangerous
chemicals.
10. This product is not to be use for medical purposes or for public information.
11. Read this instruction manual thoroughly before operating the unit.
CAUTION
1. The above content is subject to change without prior notice.
2. The information printed in this manual may be different from the actual results because of printing
limitations.
3. The manufacturer and its suppliers hold no responsibility to you or no any other person for any
damage expenses, lost profits, or any other claim arisen by improper handling, misuse or failure to
comply with the correct use of this product as described in this instruction manual.
MEASURING SPECTRAL RESPONSE:
260nm to 400nm
RF TRANSMISSION FREQUENCY:
433MHz
OPERATION TEMPERATURE:
14°F to 140°F ( -10°C to 60°C)
OUTPUT INFORMATION (UV INDEX)
RANGE:
0 TO 11 (DISPLAYED IN RECEIVING UNITS)
RESOLUTION:
1 INDEX
“Modifications not authorized by the manufacturer may void users authority to operate this device”
Operation is subject to the following two conditions: (1) this device may not cause interference, and (2)
this device must accept any interference, including interference that may cause undesired operation of
the device.
071-510320-001900
NOTE:
During the electrostatic discharge, the device may malfunction.
Please press the RESET key to return to normal operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there
is no guarantee that interference will not occur in a particular installation. If this equipment does not cause harmful interference to radio television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following
measures;
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help.